PHILADELPHIA, PA ·
OSHA Inspection: KILDARRAGH CONSTRUCTION, INC.
Programmed Other inspection · Safety discipline
At a glance
On , OSHA opened a programmed Other safety inspection of KILDARRAGH CONSTRUCTION, INC. in 616 CHRISTIAN ST., PHILADELPHIA, PA 19147 (NAICS 238140). OSHA activity number 341314052.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KILDARRAGH CONSTRUCTION, INC.
- Site address
- 616 CHRISTIAN ST.
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19147
- Mailing
- 608 SUMMIT AVE., NEWTOWN SQUARE, PA 19073
What kind of inspection was it?
- Inspection type
- Programmed Other (K)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.451 C01
- Issued
- Mar 11, 2016
- Abate by
- Mar 17, 2016
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. a) Jobsite: The supported tubular welded frame scaffold was not restrained from tipping or falling over by guying, tying, bracing, or equivalent means exposing employees engaged in stucco activities to a scaffold collapse. Noted on or about 2/27/16
Recent events (2)
- · I (S) $2100
- · Z (S) $2800
1926.451 F06
- Issued
- Mar 11, 2016
- Abate by
- Mar 17, 2016
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines were less than 10 feet. a) Jobsite: A tubular welded frame scaffold was erected in close proximity to an electrical line exposing employees engaged in stucco activities to electrical hazards. Noted on or about 2/27/16
Recent events (2)
- · I (S) $2100
- · Z (S) $2800
1926.451 G01 VII
- Issued
- Mar 11, 2016
- Abate by
- Mar 17, 2016
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Jobsite - Employees engaged in stucco activities from the third and four and level of a tubular welded frame scaffold were exposed to fall hazards at heights greater than 10 feet without the use of personal fall arrest or guardrail systems. Noted on or about 2/27/16
Recent events (2)
- · I (S) $2100
- · Z (S) $2800
More inspections in this industry (NAICS 238140)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341314052.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.