Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: KILDARRAGH CONSTRUCTION, INC.

Programmed Other inspection · Safety discipline

On , OSHA opened a programmed Other safety inspection of KILDARRAGH CONSTRUCTION, INC. in 616 CHRISTIAN ST., PHILADELPHIA, PA 19147 (NAICS 238140). OSHA activity number 341314052.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kildarragh Construction, INC. for free Get an email when a new federal OSHA severe-injury report for Kildarragh Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
616 CHRISTIAN ST.
City
PHILADELPHIA
State
PA
ZIP
19147
Mailing
608 SUMMIT AVE., NEWTOWN SQUARE, PA 19073
Inspection type
Programmed Other (K)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
Private (A)

3 citations on file for this inspection.

1926.451 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 11, 2016
Abate by
Mar 17, 2016
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph.    a) Jobsite: The supported tubular welded frame scaffold was not restrained from tipping or falling over by guying, tying, bracing, or equivalent means exposing employees engaged in stucco activities to a scaffold collapse.           Noted on or about 2/27/16
Recent events (2)
  • · I (S) $2100
  • · Z (S) $2800

1926.451 F06

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 11, 2016
Abate by
Mar 17, 2016
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines were less than 10 feet.        a) Jobsite: A tubular welded frame scaffold was erected in close proximity to an electrical line exposing employees engaged in stucco activities to electrical hazards.     Noted on or about 2/27/16
Recent events (2)
  • · I (S) $2100
  • · Z (S) $2800

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 11, 2016
Abate by
Mar 17, 2016
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    a) Jobsite - Employees engaged in stucco activities from the third and four and level of a tubular welded frame scaffold were exposed to fall hazards at heights greater than 10 feet without the use of personal fall arrest or guardrail systems.       Noted on or about 2/27/16
Recent events (2)
  • · I (S) $2100
  • · Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341314052.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.