Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: AAB MFG. HOLDINGS, L.P.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AAB MFG. HOLDINGS, L.P. in 13913 BUXLEY STREET, HOUSTON, TX 77045 (NAICS 332722). OSHA activity number 341317048.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AAB MFG. Holdings, L.P. for free Get an email when a new federal OSHA severe-injury report for AAB MFG. Holdings, L.P. is published. One employer, no account, unsubscribe in one click.
Site address
13913 BUXLEY STREET
City
HOUSTON
State
TX
ZIP
77045
Mailing
13913 BUXLEY STREET, HOUSTON, TX 77045
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332722
Employees
35
Ownership type
Private (A)

8 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $5,300 · Current $2,650 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:    At the site on or about 21 March, 2016; flammable and oxidizing gasses were improperly stored, exposing employees to fire hazards.
Recent events (2)
  • · I (S) $2650
  • · Z (S) $5300

1910.147 C01

Serious Gravity 10 2 instances 3 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $8,730 · Current $4,365 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:         a) In the loading bay area; employees perform maintenance on a Lexas band saw, model #: LX-330-NC without any energy control procedures or training, exposing employees to struck-by hazards.         b) In the threading area; employees perform maintenance on a LANDIS brand lathes, unknown model and serial number without any energy control procedures or training, exposing employees to caught-in hazards.
Recent events (2)
  • · I (S) $4365
  • · Z (S) $8730

1910.184 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $3,181 · Current $1,591 Reduced
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach:        At the site on or about March 21, 2016; employees used steel alloy slings that did not have permanently affixed durable identification tags, exposing employees to struck-by hazards.
Recent events (2)
  • · I (S) $1590.5
  • · Z (S) $3181

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $8,730 · Current $4,365 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:        At the site on or about March 21, 2016; employees an unguarded HYPNEUMAT wire brush wheel model #: S200EH6, exposing the employees to caught in hazards.
Recent events (2)
  • · I (S) $4365
  • · Z (S) $8730

1910.212 A03 II

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $8,730 · Current $4,365 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    At the site on or about March 21, 2016; employees operated equipment that was not guarded to prevent them from having any part of their body in the danger zone, exposing the employees to amputation hazards.         a) In the loading bay an employee was exposed to seven inches of unguarded blade while operating a Lexas horizontal band saw, model #: LX-330NC.        b) In the loading bay an employee was exposed to 6 inches of unguarded blade while operating a DOAL horizontal band saw, unknown model and serial number.
Recent events (2)
  • · I (S) $4365
  • · Z (S) $8730

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $5,301 · Current $2,651 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:     At the site on or about 21 March, 2016; electrical boxes on equipment employees used had unused openings at:        a) In the threading area; an employee working on a double threading machine; unknown model or serial number was exposed to an unused opening on the machines power control box, exposing the employee to electrical hazards.        b) In the threading area: an employee working on a LANDIS brand lathe; unknown model or serial number was exposed to an unused opening on the lathes power control box, exposing the employee to electrical hazards.
Recent events (2)
  • · I (S) $2650.5
  • · Z (S) $5301

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $5,300 · Current $2,650 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:        At the site on our about 21 March, 2016; in the threading area employees used a flexible cord that was not fitted with strain relief, exposing the employees to electrical hazards.
Recent events (2)
  • · I (S) $2650
  • · Z (S) $5300

1904.32 B06

Other-than-serious 1 instance 35 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $595 · Current $296 Reduced
29 CFR 1904.32(b)(6): The annual summary was not posted between February 1 of the year following the year covered by the records and kept in place until April 30 at the work site.         At the site on or about 21 March, 2016; the annual injury and illness summary was not posted by February 1st as required.
Recent events (2)
  • · I (O) $296
  • · Z (O) $595

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341317048.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.