HAUPPAUGE, NY ·
OSHA Inspection: FB LABORATORIES INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FB LABORATORIES INC. in 70 COMMERCE DRIVE, HAUPPAUGE, NY 11788 (NAICS 325412). OSHA activity number 341319408.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FB LABORATORIES INC.
- Site address
- 70 COMMERCE DRIVE
- City
- HAUPPAUGE
- State
- NY
- ZIP
- 11788
- Mailing
- 70 COMMERCE DRIVE, HAUPPAUGE, NY 11788
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325412
- Employees
- 45
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Sep 1, 2016
- Abate by
- Nov 13, 2016
- Penalty
- Initial $8,730 · Current $6,548 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Worksite, Manufacturing Department: Employees expected to perform cleaning, sanitation, and maintenance work, as per the equipment logbook, on Rimek Roll Compactor, Equipment #RC-01, were neither provided with nor utilizing energy control procedures; on or about 3/11/16. b) Worksite, Room #4: Employees expected to perform cleaning, sanitation, and maintenance work, as per the equipment logbook, on the ACG-Pam Capsule Machine were neither provided with nor utilizing energy control procedures; on or about 3/11/16. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $6547.5
- · Z (S) $8730
1910.147 C07 I
- Issued
- Sep 1, 2016
- Abate by
- Nov 13, 2016
- Penalty
- Initial $8,730 · Current $6,548 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: a) Worksite, Manufacturing Department: Employees expected to perform cleaning, sanitation, and maintenance work, as per the equipment logbook, on Rimek Roll Compactor, Equipment #RC-01, were not provided with training on utilizing energy control procedures; on or about 3/11/16. b) Worksite, Room #4: Employees expected to perform cleaning, sanitation, and maintenance work, as per the equipment logbook, on the ACG-Pam Capsule Machine were not provided with training on utilizing energy control procedures; on or about 3/11/16. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $6547.5
- · Z (S) $8730
1910.212 A01
- Issued
- Sep 1, 2016
- Abate by
- Nov 13, 2016
- Penalty
- Initial $8,730 · Current $6,548 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: a) Worksite, Manufacturing Department: Employees operating the Rimek Roll Compactor (model KERC 200/75, serial No. 1214012, manufactured by Karnavati Engineering Ltd.) were exposed to amputation hazards from rotating parts. The feed screw was not guarded through the hopper, allowing employees to come in contact with the danger zone while running the granulation process or cleaning and servicing the equipment; on or about 3/10/16. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $6547.5
- · Z (S) $8730
More inspections in this industry (NAICS 325412)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341319408.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.