OSHA Inspection: S. D. SZETELA, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of S. D. SZETELA, LLC in PERKINS ROAD, LONDONDERRY, NH 03038 (NAICS 238140). OSHA activity number 341319655.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S. D. Szetela, LLC — free Get an email when a new federal OSHA severe-injury report for S. D. Szetela, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
S. D. SZETELA, LLC
Site address
PERKINS ROAD
City
LONDONDERRY
State
NH
ZIP
03038
Mailing
P. O. BOX 222, GLEN, NH 03838
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.451 G04 I

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 28, 2016
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:    Location: Building 4  On or about 3/11/16, Employees were exposed to a 16 foot fall hazard while loading masonry block on a fabricated frame scaffold that did not have guard rails around the interior of the scaffold.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.452 C05 III

Other-than-serious 1 instance 4 exposed
Issued
Apr 28, 2016
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.452(c)(5)(iii): Brackets used to support cantilevered loads shall only be used to support personnel, unless the scaffold has been designed for other loads by a qualified engineer and built to withstand the tipping forces caused by those other loads being placed on the bracket-supported section of the scaffold.    Location: Building #4,   On or about 3/11/16, side brackets were used to support a stairway on fabricated frame scaffold that was not designed by a qualified engineer.