Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: SPIRIT DISTRIBUTION INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SPIRIT DISTRIBUTION INC. in 510 STATION AVENUE, BENSALEM, PA 19020 (NAICS 493110). OSHA activity number 341320778.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Spirit Distribution INC. for free Get an email when a new federal OSHA severe-injury report for Spirit Distribution INC. is published. One employer, no account, unsubscribe in one click.
Site address
510 STATION AVENUE
City
BENSALEM
State
PA
ZIP
19020
Mailing
510 STATION AVENUE, BENSALEM, PA 19020
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
20
Ownership type
Private (A)

4 citations on file for this inspection.

1910.22 A02

Serious Gravity 1 2 instances 4 exposed
Issued
Jul 11, 2016
Penalty
Initial $2,168 · Current $1,500 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:    a) Work floor - On or about March 14, 2016, employees were working in a production area where the work floor was cluttered with wood scraps, plastic shards, and other debris.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2168

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 11, 2016
Abate by
Sep 12, 2016
Penalty
Initial $4,250 · Current $2,250 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by the point of operation and discharge area of compactors.      a) Work floor of warehouse - On or about March 14, 2016, employees were exposed to crushing injuries within the dump area of a green trash compactor, as the compactor's gate interlock was removed and bypassed.    b) Work floor of warehouse - On or about March 14, 2016, employees were exposed to crushing injuries within the stacking area of a brown cardboard compactor, as the compactor's gate interlock was removed and bypassed.
Recent events (2)
  • · I (S) $2250
  • · Z (S) $4250

1910.303 F01

Serious Gravity 5 2 instances 4 exposed
Issued
Jul 11, 2016
Abate by
Sep 12, 2016
Penalty
Initial $4,250 · Current $2,250 Reduced
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    a) Work floor all panels - On or about March 14, 2016, employees were utilizing circuit breakers to control lighting, motor circuits and other equipment contained in a circuit breaker panel which was not legibly marked to indicate its purpose or located and arranged so the panel's purpose was evident.
Recent events (2)
  • · I (S) $2250
  • · Z (S) $4250

1910.303 G02 I

Serious Gravity 5 2 instances 4 exposed
Issued
Jul 11, 2016
Abate by
Sep 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a) Work floor main electrical panels - On or about March 14, 2016, employees were utilizing a main circuit service panel with the missing circuit breakers covered by tape, with live parts energized to 220 volts AC.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Spirit Distribution INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341320778.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.