GLENCOE, IL —
OSHA Inspection: SOLAR SERVICE INC. DBA SUN-WAY SOLAR COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SOLAR SERVICE INC. DBA SUN-WAY SOLAR COMPANY in 59 LAKEWOOD, GLENCOE, IL 60022 (NAICS 221114). OSHA activity number 341320943.
Where did this inspection happen?
- Establishment
- SOLAR SERVICE INC. DBA SUN-WAY SOLAR COMPANY
- Site address
- 59 LAKEWOOD
- City
- GLENCOE
- State
- IL
- ZIP
- 60022
- Mailing
- 7312 N. MILWAUKEE AVE., NILES, IL 60714
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221114
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 G01 III
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(iii): Each employee on a crawling board (chicken ladder) was not protected by a personal fall arrest system, a guardrail system (with minimum 200 pound toprail capacity), or by a three-fourth inch (1.9 cm) diameter grabline or equivalent handhold securely fastened beside each crawling board: a) On or about May 14, 2016, employees were exposed to the hazard of falling approximately 12 feet while on a crawling board (chicken ladder) located on the roof of the building. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1000
- — Z (S) $2400
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On or about March 14, 2016, employees were not protected from the hazard of falling approximately 30 feet while working from a roof deck without fall protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.502 E01
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.502(e)(1): Positioning device systems were not rigged such that an employee could not free fall more than 2 feet (0.9 m): a) On or about May 14, 2016, positioning devices provided for employee use on a roof surface having a pitch of approximately 14/12 were not rigged to prevent employees from falling more than 2 feet. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1000
- — Z (S) $2400
1926.1053 B22
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall: a) On or about March 14, 2016, employees were exposed to the hazard of falling approximately 12 feet when climbing a portable ladder while carrying materials between two roof deck surfaces. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1000
- — Z (S) $2400
More inspections in this industry (NAICS 221114)
BARRY, TX—2026-07-09
SOLV ENERGY, LLC
AGUADILLA, PR—2026-07-02
PURA ENERG�A INC
LOS ANGELES, CA—2026-07-01
ALTUS POWER, INC.
ROCKLIN, CA—2026-06-29
NATIONWIDE ENVIRONMENTAL AND CONSTRUCTION SERVICES
ORLANDO, FL—2026-06-26
SOLAR ROOFING CONSTRUCTION SPECIALIST CORP.
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source