Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CAMDEN CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CAMDEN CONSTRUCTION, LLC in 3907 14TH STREET, NW, WASHINGTON, DC 20011 (NAICS 238130). OSHA activity number 341331718.

Watch Camden Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Camden Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3907 14TH STREET, NW
City
WASHINGTON
State
DC
ZIP
20011
Mailing
5990 SLIGO MILL ROAD, NE, WASHINGTON, DC 20011
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

5 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  a) Second Deck - Employees were using a job made 4-way temporary electrical receptacle outlet that was listed for permanent installation use, to provide power to portable electric power tools including a Skil saw and chop saw, 15 amp, 120 volt service, on or about 03/17/2016.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $1600

1926.403 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(d)(1): Electric equipment was not firmly secured to the surface on which it was mounted:  a) Lower Level - Employees were using a 2-way temporary  electrical receptacle outlet to supply power to portable electric tools and the outlet was not mounted, 15 amp, 120 volt service, on or about 03/17/2016.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $0

1926.1052 C01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  a) Stairway - Employees were using a stairway that measured 44 inches wide, with 20 risers with a total rise of 11 feet and a handrail was not provided, on or about 03/17/2016.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $1600

1926.1052 C01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  a) Stairway - Employees were using a stairway that measured 44 inches wide, with 20 risers, with a total rise of 11 feet and was not provided with a stair rail on the unprotected side, on or about 03/17/2016.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $0

1926.501 B01

Repeat Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $5600.00 · Current $5600.00
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  a) Second Floor Rear - Employees were observed standing on an open deck preparing to set exterior wood framed wall sections and exposed to a fall hazard of up to 15 feet, on or about 03/17/2016.  Camden Construction, LLC. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(1), which was contained in OSHA inspection number 316371012, citation number 1, item number 2a, and was affirmed as a final order on July 5 2012, with respect to a workplace located at 1825 14th Street, NE Washington DC 20009.  No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (R) $5600

MACY'S