Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: C-TEC SOLAR

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of C-TEC SOLAR in 226 NORTH QUAKER LANE, WEST HARTFORD, CT 06119 (NAICS 221114). OSHA activity number 341331759.

Watch C-Tec Solar — free Get an email when a new federal OSHA severe-injury report for C-Tec Solar is published. One employer, no account, unsubscribe in one click.
Establishment
C-TEC SOLAR
Site address
226 NORTH QUAKER LANE
City
WEST HARTFORD
State
CT
ZIP
06119
Mailing
1 GRIFFIN ROAD SOUTH SUITE 200, BLOOMFIELD, CT 06002
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221114
Employees
12
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   On or about 03/17/2016 employees at the Quaker Lane construction project were exposed to approximately 15' falls.  Employees were engaged in solar panel repair without fall protection.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9m) feet above the landing.  On or about 03/17/2016 employees at the North Quaker Lane solar panel project were exposed to approximately 5' falls.  Employees ladder did not extend at least three feet above its landing.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1926.1053 B04

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  On or about 03/17/2016 employees at the North Quaker Lane solar panel repair project were exposed to approximately 5' falls.  Employees stepladder was used for purposes it was not designed for.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341331759.