OSHA Inspection: PARK OHIO ASSEMBLY COMPONENTS GROUP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PARK OHIO ASSEMBLY COMPONENTS GROUP in 3100 SE MARICAMP ROAD, OCALA, FL 34471 (NAICS 326220). OSHA activity number 341333219.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Park Ohio Assembly Components Group for free Get an email when a new federal OSHA severe-injury report for Park Ohio Assembly Components Group is published. One employer, no account, unsubscribe in one click.
Site address
3100 SE MARICAMP ROAD
City
OCALA
State
FL
ZIP
34471
Mailing
3100 SE MARICAMP RD, OCALA, FL 34471
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326220
Employees
106
Ownership type
Private (A)

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 6 exposed
Issued
May 26, 2016
Abate by
Jul 14, 2016
Penalty
Initial $7,000 · Current $7,000
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, exposing employees to amputation hazards.   a).  On or about March 16, 2016 employees operating the NRM 4-1/2" Cold fed rubber extrusion machines are exposed to amputation hazards because the process the employee uses to attach the hose end of one reel to the beginning hose of the next reel for continuous feed into the machine, created a condition where an employee's thumb was entangled in the thin Kevlar cord used to tie off the two ends, resulting in amputations of the thumb.
Recent events (2)
  • · I (S) $7000
  • · Z (S) $7000

1910.212 A03 II

Deleted Repeat Gravity 10 4 instances 6 exposed
Issued
May 26, 2016
Penalty
Initial $35,000 · Current $0 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.  a). On or about March 16, 2016 employees are conducting reel to reel changes for continuous extruded rubber application to high pressure rubber hose. While the machine is still running the employee must use a cord to tie the end of one hose reel to the beginning of the next hose reel ensuring continuous operation of the extruder machines without shutting the machines down.
Recent events (2)
  • · I (R) $0
  • · Z (R) $35000

View Park Ohio Assembly Components Group's full OSHA safety record →