Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: COOPERATIVE PRODUCERS, INC. - HAYLAND

Fatality or catastrophe inspection · Safety discipline

On , OSHA opened a fatality or catastrophe safety inspection of COOPERATIVE PRODUCERS, INC. - HAYLAND in 7940 N. HAYLAND AVE, PROSSER, NE 68883 (NAICS 424510). OSHA activity number 341333342.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cooperative Producers, INC. - Hayland for free Get an email when a new federal OSHA severe-injury report for Cooperative Producers, INC. - Hayland is published. One employer, no account, unsubscribe in one click.
Site address
7940 N. HAYLAND AVE
City
PROSSER
State
NE
ZIP
68883
Mailing
265 N. SHOWBOAT BLVD. P.O. BOX 1008, HASTINGS, NE 68902
Inspection type
Fatality or catastrophe (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
9
Ownership type
Private (A)

5 citations on file for this inspection.

1910.219 M01 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Sep 9, 2016
Penalty
Initial $12,471 · Current $0 Reduced
29 CFR 1910.219(m)(1)(i): Installed guards were not secured by the use of the following materials:  expanded metal, perforated or solid sheet metal, wire mesh on a frame of angle iron, or iron pipe securely fastened to floor or to frame of machine:  The employer is failing to protect employees from hazards such as amputation and crushing injuries by not ensuring that belt and pulley guards were properly secured. This was most recently documented at a worksite at 7940 Hayland Avenue, Prosser, Nebraska on March 15 and March 16, 2016.  The expanded metal machine guards for the belt and pulley system for the sub-floor auger motors for West McPherson/Bin 31 and for East McPherson/Bin 32 were not properly secured after multiple belt change-out procedures.
Recent events (3)
  • · F (S) $0
  • · C (S) $12471
  • · Z (S) $12471

1910.272 G01 III

Other-than-serious 2 instances 6 exposed
Issued
Sep 9, 2016
Abate by
Dec 28, 2018
Penalty
Initial $12,471 · Current $2,471 Reduced

Hazardous substances 0560X100

29 CFR 1910.272(g)(1)(iii): The atmosphere within a bin, silo, or tank in the grain handling facility was not tested for oxygen content prior to employee entry.    The employer is failing to protect employees from the respiratory hazard of oxygen deficiency.  This was most recently documented at a worksite located at or near 7940 N. Hayland Avenue, Prosser, Nebraska on March 16, 2016.  Employee(s) entered the West McPherson/Bin 31 of soybeans on March 16, 2016, without monitoring for oxygen content prior to or during entry. The initial employee entrant was attempting to clear clogged sub-floor auger openings to remove soybeans from the bin.
Recent events (3)
  • · F (O) $2471
  • · C (S) $12471
  • · Z (S) $12471

1910.272 M04

Serious Gravity 10 2 instances 3 exposed
Issued
Sep 9, 2016
Abate by
Dec 28, 2018
Penalty
Initial $12,471 · Current $12,471
29 CFR 1910.272(m)(4): The employer did not implement procedures in the grain handling facility for the use of tags and locks which would prevent the inadvertent application of energy or motion to equipment being repaired, serviced, or adjusted, which could result in employee injury:    The employer is failing to protect employees from amputation and crushing injuries from the unexpected start-up of equipment by not ensuring that each authorized employee affixed a personal lockout or tagout device to the group lockout device, group lockbox, or comparable mechanism, during the replacement of belts on the belt and pulley system for the West McPherson / Bin 31 sub-floor auger motor. This was most recently documented on March 14 and March 15, 2016, when two employees worked together to replace defective belts for the sub-floor auger motor.
Recent events (3)
  • · F (S) $12471
  • · C (S) $12471
  • · Z (S) $12471

1910.272 G01 II

Willful Gravity 10 1 instance 3 exposed
Issued
Sep 9, 2016
Abate by
Dec 28, 2018
Penalty
Initial $124,709 · Current $124,709
29 CFR 1910.272(g)(1)(ii): Prior to bin entry, all mechanical, electrical, hydraulic, and pneumatic equipment which presented a danger to employees inside grain storage structures in the grain handling facility were not disconnected, locked out and tagged, blocked-off, or otherwise prevented from operating by other equally effective means or methods:    The employer is failing to protect each employee entering a grain storage bin from hazards including, but not limited to amputation, entanglement, crushing injuries, and engulfment by not de-energizing, locking and tagging out the electrical sub-floor auger, or otherwise preventing it from operating by implementing other equally effective means. This was most recently documented at a worksite located at 7940 Hayland Avenue, Prosser, Nebraska under the following circumstances:    (a) On March 14, 2016 when employee #1 entered West McPherson/Bin 31 to use a rod or pole to help clear soybean debris that was clogging sump/floor openings during the operation of the sub-floor auger.  At the time of entry, Bin 31 contained approximately 50,000 to 60,000 bushels of soybeans.     (b) On March 15, 2016 when employees #2 and #3 entered West McPherson/Bin 31 to use a rod or pole to help clear soybean debris that was clogging sump/floor openings during the operation of the sub-floor auger. At the time of entry, Bin 31 contained approximately 50,000 to 60,000 bushels of soybeans.     To abate this violation, the employer must assure that each time an employee enters a grain storage structure at the facility, all mechanical, electrical, hydraulic, and pneumatic equipment that presents a danger to employees inside the structure is de-energized, disconnected, locked out, tagged out, blocked-off, or otherwise effectively prevented from operating.
Recent events (3)
  • · F (W) $124709
  • · C (W) $124709
  • · Z (W) $124709

1910.272 G01 II

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 9, 2016
Abate by
Dec 28, 2018
Penalty
Initial $124,709 · Current $12,471 Reduced
29 CFR 1910.272(g)(1)(ii): Prior to bin entry, all mechanical, electrical, hydraulic, and pneumatic equipment which presented a danger to employees inside grain storage structures in the grain handling facility were not disconnected, locked out and tagged, blocked-off, or otherwise prevented from operating by other equally effective means or methods:    The employer is failing to protect each employee entering a grain storage bin from hazards including, but not limited to amputation, entanglement, crushing injuries, and engulfment by not de-energizing, locking out, and tagging out the electrical sub-floor auger. This was most recently documented at a worksite located at 7940 Hayland Avenue, Prosser, Nebraska on March 16, 2016, Employee #3 entered West McPherson/Bin 31 to use a conduit pole to help clear soybean debris that was clogging unguarded sump/floor openings during the operation of the sub-floor auger. At the time of entry, Bin 31 contained approximately 50,000 to 60,000 bushels of soybeans. On March 16, 2016, employee #3 was fatally injured by asphyxiation when his rope lifeline became entangled with the running sub-floor auger in Bin 31.      To abate this violation, the employer must assure that each time an employee enters a grain storage structure at the facility, all mechanical, electrical, hydraulic, and pneumatic equipment is de-energized, disconnected, locked out, tagged out, blocked-off, or otherwise effectively prevented from operating. 29 CFR 1910.272(g)(1)(ii): Prior to bin entry, all mechanical, electrical, hydraulic, and pneumatic equipment which presented a danger to employees inside grain storage structures in the grain handling facility were not disconnected, locked out and tagged, blocked-off, or otherwise prevented from operating by other equally effective means or methods:  The employer is failing to protect each employee entering a grain storage bin from hazards including, but not limited to amputation, entanglement, crushing injuries, and engulfment by not de-energizing, locking out, and tagging out the electrical sub-floor auger. This was most recently documented at a worksite located at 7940 Hayland Avenue, Prosser, Nebraska on March 15, 2016, when employees #2 and #3 entered West McPherson/Bin 31 to use a rod or pole to help clear soybean debris that was clogging unguarded sump/floor openings during the operation of the sub-floor auger. At the time of entry, Bin 31 contained approximately 50,000 to 60,000 bushels of soybeans.  To abate this violation, the employer must assure that each time an employee enters a grain storage structure at the facility, all mechanical, electrical, hydraulic, and pneumatic equipment is de-energized, disconnected, locked out, tagged out, blocked-off, or otherwise effectively prevented from operating.
Recent events (3)
  • · F (S) $12471
  • · C (W) $124709
  • · Z (W) $124709

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341333342.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.