Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: BONNEVILLE POWER ADMINISTRATION ROSS COMPLEX

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of BONNEVILLE POWER ADMINISTRATION ROSS COMPLEX in 5411 NE HWY 99, VANCOUVER, WA 98666 (NAICS 221122). OSHA activity number 341337194.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bonneville Power Administration Ross Complex for free Get an email when a new federal OSHA severe-injury report for Bonneville Power Administration Ross Complex is published. One employer, no account, unsubscribe in one click.
Site address
5411 NE HWY 99
City
VANCOUVER
State
WA
ZIP
98666
Mailing
P.O. BOX 491 MAIL STOP NF-WHSE-EAST, VANCOUVER, WA 98663
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221122
Employees
800
Ownership type
Federal government (D)

4 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 23, 2016
Abate by
Jul 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.  A)     At the hazardous waste building, in the upper drain bay, there was a flexible cord that was running across the floor creating a tripping hazard
Recent events (1)
  • · Z (S) $0

1910.176 B

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 23, 2016
Abate by
Aug 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.176(b): Storage of material created a hazard:  A)     In the warehouse, there was a set of metal racks that had been struck by a forklift, and were damaged to the point that other metal members were showing signs of fatigue.
Recent events (1)
  • · Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 23, 2016
Abate by
Jul 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  A)     At the Hazardous materials building, in the upper drain bay area, there was a bench grinder that did not have a tongue guard installed over the grinding wheel.
Recent events (1)
  • · Z (S) $0

1910.305 B02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 23, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  A)     In the Warehouse there was a wall outlet that did not have a proper cover.
Recent events (1)
  • · Z (S) $0

View Bonneville Power Administration Ross Complex's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341337194.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.