Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARTCO-BELL CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ARTCO-BELL CORPORATION in 1302 INDUSTRIAL BLVD, TEMPLE, TX 76504 (NAICS 337127). OSHA activity number 341339190.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Artco-Bell Corporation — free Get an email when a new federal OSHA severe-injury report for Artco-Bell Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1302 INDUSTRIAL BLVD
City
TEMPLE
State
TX
ZIP
76504
Mailing
1302 INDUSTRIAL BLVD, TEMPLE, TX 76504
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337127
Employees
362
Ownership type
A

7 citations on file for this inspection.

1910.178 G02

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 15, 2016
Abate by
Jun 21, 2016
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.178(g)(2): Battery changing and charging installations for industrial trucks were not provided with facilities for flushing and neutralizing spilled electrolyte:  On or about March 21, 2016 and in times prior thereto an eye wash station was not provided near an Amertek/Prestolite Power AC 500 battery charger, exposing employees to the hazards of corrosive chemical splashes.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.178 P01

Serious Gravity 1 1 instance 10 exposed
Issued
Jun 15, 2016
Abate by
Jun 21, 2016
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition:  On or about March 21, 2016 and in times prior thereto the warning decals on Cat Propane forklift number 65 were illegible, exposing employees to the hazards of being stuck by forklifts.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

1910.184 E01

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 15, 2016
Abate by
Jun 21, 2016
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach:  On or about March 21, 2016 and in times prior thereto the chain slings used to lift molds weighing up to 9578 pounds did not have an identification tag attached them exposing employees to the  hazards of being stuck by falling loads in the injection area.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.303 B01 II

Serious Gravity 5 2 instances 10 exposed
Issued
Jun 15, 2016
Abate by
Jun 21, 2016
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:  On or about March 21, 2016 and in time prior thereto the safety devices preventing the 480 volt disconnects from being opened while in the on position were broken creating a arc flash hazard in the molding area on the following disconnects:  a. Panel K, located on line 1. b. Panel L, located on line 2.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.303 F02

Serious Gravity 5 2 instances 10 exposed
Issued
Jun 15, 2016
Abate by
Jun 21, 2016
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  On or about March 21, 2016 and in times prior thereto the circuit breakers were not identified, located in panel LINE 1 LV PANEL, found in the assemble area. This condition created an electrical shock hazard of 120/240 volts.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

1910.304 G05

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 15, 2016
Abate by
Jun 21, 2016
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  On or about March 21, 2016 and in times prior thereto a 120 volt wall outlet had an open ground, the outlet was located in the shipping area.  This condition crated an hazard of electrical shock to any worker using the outlet.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

1910.305 B01 II

Serious Gravity 1 2 instances 4 exposed
Issued
Jun 15, 2016
Abate by
Jun 21, 2016
Penalty
Initial $3,000 · Current $1,800 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  On or about March 21, 2016 and in times prior thereto knockout plugs were needed in the following areas creating a hazard of electrical burns:  a.  1 inch diameter opening in 480 volt battery charger, located in the shipping area. b.  1 inch x 2 inch blank breaker opening in 480 volt HV panel, located in molding area.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3000

View Artco-Bell Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341339190.