TEMPLE, TX —
OSHA Inspection: ARTCO-BELL CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ARTCO-BELL CORPORATION in 1302 INDUSTRIAL BLVD, TEMPLE, TX 76504 (NAICS 337127). OSHA activity number 341339190.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARTCO-BELL CORPORATION
- Site address
- 1302 INDUSTRIAL BLVD
- City
- TEMPLE
- State
- TX
- ZIP
- 76504
- Mailing
- 1302 INDUSTRIAL BLVD, TEMPLE, TX 76504
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337127
- Employees
- 362
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.178 G02
- Issued
- Jun 15, 2016
- Abate by
- Jun 21, 2016
- Penalty
- Initial $4,000 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.178(g)(2): Battery changing and charging installations for industrial trucks were not provided with facilities for flushing and neutralizing spilled electrolyte: On or about March 21, 2016 and in times prior thereto an eye wash station was not provided near an Amertek/Prestolite Power AC 500 battery charger, exposing employees to the hazards of corrosive chemical splashes.
Recent events (2)
- — I (S) $2400
- — Z (S) $4000
1910.178 P01
- Issued
- Jun 15, 2016
- Abate by
- Jun 21, 2016
- Penalty
- Initial $3,000 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition: On or about March 21, 2016 and in times prior thereto the warning decals on Cat Propane forklift number 65 were illegible, exposing employees to the hazards of being stuck by forklifts.
Recent events (2)
- — I (S) $1800
- — Z (S) $3000
1910.184 E01
- Issued
- Jun 15, 2016
- Abate by
- Jun 21, 2016
- Penalty
- Initial $4,000 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: On or about March 21, 2016 and in times prior thereto the chain slings used to lift molds weighing up to 9578 pounds did not have an identification tag attached them exposing employees to the hazards of being stuck by falling loads in the injection area.
Recent events (2)
- — I (S) $2400
- — Z (S) $4000
1910.303 B01 II
- Issued
- Jun 15, 2016
- Abate by
- Jun 21, 2016
- Penalty
- Initial $4,000 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: On or about March 21, 2016 and in time prior thereto the safety devices preventing the 480 volt disconnects from being opened while in the on position were broken creating a arc flash hazard in the molding area on the following disconnects: a. Panel K, located on line 1. b. Panel L, located on line 2.
Recent events (2)
- — I (S) $2400
- — Z (S) $4000
1910.303 F02
- Issued
- Jun 15, 2016
- Abate by
- Jun 21, 2016
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On or about March 21, 2016 and in times prior thereto the circuit breakers were not identified, located in panel LINE 1 LV PANEL, found in the assemble area. This condition created an electrical shock hazard of 120/240 volts.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
1910.304 G05
- Issued
- Jun 15, 2016
- Abate by
- Jun 21, 2016
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about March 21, 2016 and in times prior thereto a 120 volt wall outlet had an open ground, the outlet was located in the shipping area. This condition crated an hazard of electrical shock to any worker using the outlet.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
1910.305 B01 II
- Issued
- Jun 15, 2016
- Abate by
- Jun 21, 2016
- Penalty
- Initial $3,000 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about March 21, 2016 and in times prior thereto knockout plugs were needed in the following areas creating a hazard of electrical burns: a. 1 inch diameter opening in 480 volt battery charger, located in the shipping area. b. 1 inch x 2 inch blank breaker opening in 480 volt HV panel, located in molding area.
Recent events (2)
- — I (S) $1800
- — Z (S) $3000
More inspections at Artco-Bell Corporation
View Artco-Bell Corporation's full OSHA safety record →
More inspections in this industry (NAICS 337127)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341339190.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.