Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: C&J CONSTRUCTION AND ROOFING LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of C&J CONSTRUCTION AND ROOFING LLC in 80 CENTRE STREET, RUMFORD, RI 02916 (NAICS 238160). OSHA activity number 341340602.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C&J Construction and Roofing LLC — free Get an email when a new federal OSHA severe-injury report for C&J Construction and Roofing LLC is published. One employer, no account, unsubscribe in one click.
Site address
80 CENTRE STREET
City
RUMFORD
State
RI
ZIP
02916
Mailing
36 GROVER STREET, NORTH PROVIDENCE, RI 02904
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

14 citations on file for this inspection.

1926.102 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 4, 2016
Penalty
Initial $3,080 · Current $1,540 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    (a) Worksite - Front Scaffold Area:  On or about 3/22/2016, eye and face protective equipment was not used when employees were operating pneumatic nail guns. .
Recent events (2)
  • — I (S) $1540
  • — Z (S) $3080

1926.451 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 4, 2016
Penalty
Initial $3,080 · Current $1,540 Reduced
29 CFR 1926.451(a)(1): Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it:     (a) Worksite - Front Scaffold:  On or about 3/22/2016, the employer did not ensure that the erected ladder jack scaffold, with unrated wood planking, was capable of supporting the intended load.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $3080

1926.451 B02 I

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 4, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(2)(i): Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold was not at least 12 inches (30 cm) wide:   (a) Worksite - Front Scaffold:  On or about 3/22/2016 employees were working from a ladder jack scaffold platform that was not a minimum of 12 inches wide.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B05 II

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 4, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end:  (a) Worksite - Front Scaffold:  On or about 3/22/2016, a ladder jack scaffold platform extended beyond it's support more than 18 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 10 2 instances 3 exposed
Issued
Apr 4, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:  (a) Worksite - Front and Rear Scaffold:  On or about 3/22/2016, proper access to ladder jack scaffolds was not provided.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 10 2 instances 3 exposed
Issued
Apr 4, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:   (a) Worksite:  On or about 3/22/2016, employees were not protected from falling while working from a ladder jack scaffold that was greater than 10 feet above a lower level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 K05

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 4, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.452(k)(5): Scaffold platforms were bridged on to another:  (a) Worksite - Front Scaffold:  On or about 3/22/2016, the employer set-up a ladder jack scaffold system with wooden planking bridged on the center extension ladder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 10 2 instances 3 exposed
Issued
Apr 4, 2016
Penalty
Initial $3,080 · Current $1,540 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:     (a) Worksite - Rear Scaffold and Side of House:  On or about 3/22/2016, employees were not protected from falling while using a ladder that did not extend at least three feet above the upper landing surface.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $3080

1926.1053 B15

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 4, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and/or after an occurrence that could have affected their safe use:   (a) Worksite - Front Scaffold:  On or about 3/22/2016, employees were exposed to fall hazards from a ladder which had not been inspected for visible defects.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B16

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 4, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:  (a) Worksite - Front Scaffold:  On or about 3/22/2016, a damaged portable extension ladder being used to support a ladder jack scaffold system was not withdrawn from service.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.100 A

Repeat Gravity 5 1 instance 4 exposed
Issued
Apr 4, 2016
Penalty
Initial $4,400 · Current $2,200 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:     (a) Worksite:  On or about 3/22/2016, employees were not protected from overhead hazards while working below roofers.     C & J Construction and Roofing LLC was previously cited for a violation of this occupational safety and health standard, 29 CFR 1926.100(a), which was contained in OSHA inspection number 1072641, citation number 001, item number 01 and was affirmed as a final order on 8/24/2015, with respect to a workplace located at 158 Doyle Street, Providence RI 02905.
Recent events (2)
  • — I (R) $2200
  • — Z (R) $4400

1926.501 B13

Repeat Gravity 10 1 instance 3 exposed
Issued
Apr 4, 2016
Penalty
Initial $6,160 · Current $3,080 Reduced
29 CFR 1926.501(b)(13): Each employees engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):     (a)  Worksite:  On or about 3/22/2016, employees were not protected from falling while working on a roof greater than six feet above a lower level.    C&J Construction and Roofing LLC was previously cited for a violation of this occupational safety and health standard, 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1072641, citation number 001, item number 02 and was affirmed as a final order on 8/24/2015, with respect to a workplace located at 158 Doyle Street, Providence RI, 02905.
Recent events (2)
  • — I (R) $3080
  • — Z (R) $6160

1926.451 F07

Other-than-serious 1 instance 3 exposed
Issued
Apr 4, 2016
Abate by
May 18, 2016
Penalty
Initial $440 · Current $220 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; Such activities were not performed by experienced and trained employees selected for such work by the competent person:    (a) Worksite:  On or about 3/22/2016, ladder jack scaffolding was not erected under the direction of a competent person.
Recent events (2)
  • — I (O) $220
  • — Z (O) $440

1926.503 A01

Other-than-serious 1 instance 3 exposed
Issued
Apr 4, 2016
Abate by
May 18, 2016
Penalty
Initial $440 · Current $220 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:     (a) Worksite:  On or about 3/22/2016, the employer did not provide adequate training for the employees who might be exposed to fall hazards.
Recent events (2)
  • — I (O) $220
  • — Z (O) $440

View C&J Construction and Roofing LLC's full OSHA safety record →