BELFAST, ME —
OSHA Inspection: NORTHEAST EQUIPMENT & SUPPLY CO.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORTHEAST EQUIPMENT & SUPPLY CO. in 17 BELMONT AVE., BELFAST, ME 04915 (NAICS 238160). OSHA activity number 341342632.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORTHEAST EQUIPMENT & SUPPLY CO.
- Site address
- 17 BELMONT AVE.
- City
- BELFAST
- State
- ME
- ZIP
- 04915
- Mailing
- 1050 WALDO STATION ROAD, WALDO, ME 04915
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B11
- Issued
- Mar 31, 2016
- Abate by
- Apr 8, 2016
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: Bank - Three employees roofing the 10/12 pitch roof with the eves greater than nine feet above the ground were not protected from falling.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.1053 B01
- Issued
- Mar 31, 2016
- Abate by
- Apr 8, 2016
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: Bank - The portable extension ladder used to access the bank's roof was not extended at least 3 feet above the roof edge.
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
More inspections at Northeast Equipment & Supply CO.
View Northeast Equipment & Supply CO.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in ME
Source