Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: GENERAL ALUMINUM MFG COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GENERAL ALUMINUM MFG COMPANY in 1370 CHAMBERLAIN BLVD., CONNEAUT, OH 44030 (NAICS 331523). OSHA activity number 341345635.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Aluminum MFG Company for free Get an email when a new federal OSHA severe-injury report for General Aluminum MFG Company is published. One employer, no account, unsubscribe in one click.
Site address
1370 CHAMBERLAIN BLVD.
City
CONNEAUT
State
OH
ZIP
44030
Mailing
1370 CHAMBERLAIN BLVD., CONNEAUT, OH 44030
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331523
Employees
268
Ownership type
Private (A)

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 2, 2016
Abate by
Sep 23, 2016
Penalty
Initial $12,471 · Current $12,471
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about March 12, 2016, employees were exposed to machine hazards when employees failed to utilize Respondent's LOTO procedure notwithstanding, the fact that employees were trained on the LOTO procedure.
Recent events (3)
  • · F (S) $12471
  • · C (S) $12471
  • · Z (S) $12471

1910.147 C04 II B

Repeat Gravity 10 1 instance 2 exposed
Issued
Sep 2, 2016
Abate by
Sep 13, 2016
Penalty
Initial $68,591 · Current $68,591
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:      On or about March 12, 2016, the employer failed to document procedure on energy sources on a MOH 540 Tilt Mold Table.       Park Ohio Products Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(4)(ii)(B), which was contained in OSHA inspection number 457493, citation number 01, item number 001 and was affirmed as a final order on August 21, 2012, with respect to a workplace located at 7000 Denison Avenue, Cleveland, Ohio 44102.
Recent events (3)
  • · F (R) $68591
  • · C (R) $68591
  • · Z (R) $68591

1910.147 C06 I

Repeat Gravity 10 1 instance 2 exposed
Issued
Sep 2, 2016
Abate by
Oct 11, 2016
Penalty
Initial $68,591 · Current $68,591
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    On or about March 12, 2016, the employer failed to conduct its annual audits on a MOH 540 Tilt Mold Table.       General Aluminum Manufacturing Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(6)(i) which was contained in OSHA inspection number 892433, citation number 01, item number 002a and was affirmed as a final order on August 6, 2013, with respect to a workplace located at 5159 S. Prospect Street, Ravenna, Ohio 44266.
Recent events (3)
  • · F (R) $68591
  • · C (R) $68591
  • · Z (R) $68591

1910.147 D

Deleted Repeat Gravity 10 1 instance 2 exposed
Issued
Sep 2, 2016
Abate by
Sep 13, 2016
Penalty
Initial $68,591 · Current $0 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about March 12, 2016, employees were exposed to machine hazards associated with pressurized hydraulic, pneumatic, electrical, and gravity as sources of energy. The employer failed to implement energy control application steps as the MOH 540 Tilt Mold Table was not shut down or turned off to perform the servicing work. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)] and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.   General Aluminum Mfg Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(d)(4)(i), which was contained in OSHA inspection number 892433, citation number 01, item number 001B and was affirmed as a final order on August 16, 2013, with respect to a workplace located at 5159 S. Prospect Street, Ravenna, Ohio 44266.   General Aluminum Mfg Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(d)(3), which was contained in OSHA inspection number 943017 citation number 02 item number 001A and was affirmed as a final order on May 17, 2015, with respect to a workplace located at 1370 Chamberlin Blvd, Conneaut, Oh, 44030.  General Aluminum Mfg Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(d)(4)(i), which was contained in OSHA inspection number 943017 citation number 02 item number 002A and was affirmed as a final order on May 17, 2015, with respect to a workplace located at 1370 Chamberlin Blvd, Conneaut, Oh, 44030.
Recent events (3)
  • · F (R) $0
  • · C (R) $68591
  • · Z (R) $68591

1910.147 F03 I

Deleted Repeat Gravity 10 1 instance 2 exposed
Issued
Sep 2, 2016
Abate by
Sep 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft:  On or about March 12, 2016, employees were exposed to machine hazards associated with pressurized hydraulic, pneumatic, electrical, and gravity as sources of energy. The employer failed to implement energy control application steps as the MOH 540 Tilt Mold Table was not shut down or turned off to perform the servicing work. As a result, the remaining applicable energy control elements, involving group lockout were not performed.   General Aluminum Mfg Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(d)(4)(i), which was contained in OSHA inspection number 892433, citation number 01, item number 001B and was affirmed as a final order on August 16, 2013, with respect to a workplace located at 5159 S. Prospect Street, Ravenna, Ohio 44266.   General Aluminum Mfg Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(d)(3), which was contained in OSHA inspection number 943017 citation number 02 item number 001A and was affirmed as a final order on May 17, 2015, with respect to a workplace located at 1370 Chamberlin Blvd, Conneaut, Oh, 44030.  General Aluminum Mfg Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(d)(4)(i), which was contained in OSHA inspection number 943017 citation number 02 item number 002A and was affirmed as a final order on May 17, 2015, with respect to a workplace located at 1370 Chamberlin Blvd, Conneaut, Oh, 44030.
Recent events (3)
  • · F (R) $0
  • · C (R) $0
  • · Z (R) $0

View General Aluminum MFG Company's full OSHA safety record →