WESTON, WI ·
OSHA Inspection: ADC CUSTOM PRODUCTS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADC CUSTOM PRODUCTS LLC in 7102 ZINSER STS., WESTON, WI 54476 (NAICS 333111). OSHA activity number 341347722.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADC CUSTOM PRODUCTS LLC
- Site address
- 7102 ZINSER STS.
- City
- WESTON
- State
- WI
- ZIP
- 54476
- Mailing
- 7102 ZINSER STS., WESTON, WI 54476
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333111
- Employees
- 43
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.147 C07 I B
- Issued
- Jun 2, 2016
- Abate by
- Jun 30, 2016
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: The employer did not train affected employees on the purpose and use of energy control procedures on equipment such as the Mazak Super Turbo-X510 MkII CNC Laser cutting machine and ACCURPRESS Model No. 717510 hydraulic brake press.
Recent events (2)
- · I (S) $1487.5
- · Z (S) $2975
1910.147 C06 I
- Issued
- Jun 2, 2016
- Abate by
- Jun 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: The employer did not conduct periodic inspections of their energy control procedures for equipment such as, but not limited to, the Mazak Super Turbo-X510 MkII CNC Laser cutting machine and ACCURPRESS Model No. 717510 hydraulic brake press.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A01
- Issued
- Jun 2, 2016
- Abate by
- Jul 15, 2016
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) A Mazak Super Turbo-X510 MkII CNC laser cutting machine located in the production room did not have effective guarding to prevent employees from entering the danger area created by the traverser as it brought product from the laser to the product table, exposing them to crushed by hazards. (b) A Wilton Model 2380 auto-feeding drill press located in the production room was not equipped with guarding to prevent employee access to the rotating parts and chips created by the chuck and drill bit. (c) A Clausing 20 auto-feeding drill press located in the production room was not equipped with guarding to prevent employee access to the rotating parts and chips created by the chuck and drill bit. (d) A manually operated Enco Milling machine located in the production room did not have the drive belt and pulley guarded to prevent employees from accessing the ingoing nip points and rotating parts. (e) A New England Butt Co. BIO-32H braiding machine located in the production room did not have adequate guarding to prevent employee access to the pinch points created by the thread and the rotating spools.
Recent events (2)
- · I (S) $1487.5
- · Z (S) $2975
1910.212 A03 II
- Issued
- Jun 2, 2016
- Abate by
- Jul 15, 2016
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): An ACCURPRESS Model No. 717510 hydraulic brake press located in the production room did not have any form of guarding to prevent employees from accessing the point of operation during the operating cycle.