OSHA Inspection: DEFCON FORCE, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of DEFCON FORCE, LLC in 725 US 52, ABERDEEN, OH 45101 (NAICS 811310). OSHA activity number 341348977.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Defcon Force, LLC for free Get an email when a new federal OSHA severe-injury report for Defcon Force, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DEFCON FORCE, LLC
Site address
725 US 52
City
ABERDEEN
State
OH
ZIP
45101
Mailing
4244 MT. PLEASANT SUITE 100, NORTH CANTON, OH 44720
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
13
Ownership type
Private (A)

2 citations on file for this inspection.

1910.146 C05 II A

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2016
Abate by
Nov 2, 2016
Penalty
Initial $8,730 · Current $0 Reduced
29 CFR 1910.146(c)(5)(ii)(A): Any conditions making it unsafe to remove an entrance cover shall be eliminated before the cover is removed.   a) Prior to the into the 4-C pulverizer on March 20, 21016 the employer did not ensure that the burner line was isolated and cleaned out to prevent re-entry of the residual coal left in the line back into the discharge chute.
Recent events (2)
  • · I (S) $0
  • · Z (S) $8730

1910.146 D02

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 15, 2016
Abate by
Nov 2, 2016
Penalty
Initial $8,730 · Current $5,000 Reduced
29 CFR 1910.146(d)(2): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not identify and evaluate the hazards of permit spaces before employees entered:    a) Prior to the entry into the 4-C pulverizer on March 20, 21016 the employer did identify all the hazards in that they did not confirm that the burner line was isolated and cleaned out to prevent re-entry of the residual coal left in the lines back into the discharge chute.
Recent events (2)
  • · I (S) $5000
  • · Z (S) $8730

View Defcon Force, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341348977.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.