RIDGELAND, MS ·
OSHA Inspection: ROMAN O. INGRAM, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROMAN O. INGRAM, INC. in 701 HARBOR PINES DRIVE, RIDGELAND, MS 39157 (NAICS 238310). OSHA activity number 341349769.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROMAN O. INGRAM, INC.
- Site address
- 701 HARBOR PINES DRIVE
- City
- RIDGELAND
- State
- MS
- ZIP
- 39157
- Mailing
- 386 GREEN OAK LANE, MADISON, MS 39110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- May 6, 2016
- Abate by
- May 12, 2016
- Penalty
- Initial $2,520 · Current $1,368 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: (a) Front Entrance - On or about March 23, 2016 an employee was exposed to a fall hazard due to the fact a scaffold was not fully decked or planked. This scaffold was 14 feet 1 inch above concrete.
Recent events (2)
- · I (S) $1368
- · Z (S) $2520
1926.451 E01
- Issued
- May 6, 2016
- Abate by
- May 12, 2016
- Penalty
- Initial $2,520 · Current $1,367 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. (a) Front Entrance - On or about March 23, 2016 an employee was exposed to a fall hazard while working on a scaffold 14 feet 1 inch above concrete with no ladder installed. The employee climbed the scaffold frame to reach the top platform.
Recent events (2)
- · I (S) $1367
- · Z (S) $2520
1926.451 G01
- Issued
- May 6, 2016
- Abate by
- May 12, 2016
- Penalty
- Initial $2,520 · Current $1,366 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. (a) Front Entrance - On or about March 23, 2016 an employee was exposed to a fall hazard while working on a scaffold 14 feet 1 inch above concrete with no guardrail installed.
Recent events (2)
- · I (S) $1366
- · Z (S) $2520
1926.451 F03
- Issued
- May 6, 2016
- Abate by
- May 10, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. (a) Front Entrance - On or about March 23, 2016 an employee was exposed to a fall hazard due to the fact a scaffold 14 feet 1 inch above concrete was not inspected prior to use. This scaffold: 1) was not fully decked or planked 2) had no guardrails installed 3) had no ladders installed
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Roman O. Ingram, INC.
View Roman O. Ingram, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238310)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341349769.