TEWKSBURY, MA ·
OSHA Inspection: BREAKAWAY ICE, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BREAKAWAY ICE, LLC in 20 CARTER STREET, TEWKSBURY, MA 01876 (NAICS 713940). OSHA activity number 341355808.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BREAKAWAY ICE, LLC
- Site address
- 20 CARTER STREET
- City
- TEWKSBURY
- State
- MA
- ZIP
- 01876
- Mailing
- 20 CARTER STREET, TEWKSBURY, MA 01876
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713940
- Employees
- 11
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Apr 18, 2016
- Abate by
- May 21, 2016
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Location - 20 Carter Street, Tewksbury, MA: On or about 3/29/2016, a program consisting of energy control procedures, employee training, and periodic inspection has not been developed and implemented to protect employees performing service and maintenance on machines and equipment from the hazards associated with unexpected energization, startup, or the release of stored energy.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1910.147 D05 I
- Issued
- Apr 18, 2016
- Abate by
- May 21, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: (a) Location - 20 Carter Street, Tewksbury, MA: On or about 3/19/2016, mechanical energy stored by the vertical auger was not relieved or restrained prior to clearing ice from the discharge chute of a Zamboni Ice Resurfacer.