UNCASVILLE, CT ·
OSHA Inspection: TECH-AIR, INCORPORATED
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TECH-AIR, INCORPORATED in 152 ROUTE 163, UNCASVILLE, CT 06382 (NAICS 332322). OSHA activity number 341356178.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TECH-AIR, INCORPORATED
- Site address
- 152 ROUTE 163
- City
- UNCASVILLE
- State
- CT
- ZIP
- 06382
- Mailing
- 152 ROUTE 163, UNCASVILLE, CT 06382
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 13
- Ownership type
- Private (A)
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 9, 2016
- Abate by
- Sep 27, 2016
- Penalty
- Initial $1,600 · Current $1,040 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that, employees were exposed to crushing hazards: Dock Area: On, or about, March 24, 2016, the underhung monorail crane and hoist was not subject to regular inspections and was not maintained in a safe operating condition. At the time of the inspection, the crane/hoist was not provided with proper markings and labels, the running rope was worn including a broken wire, flattening and birdcaging, a sheave appeared to be worn and the upper limit switch was either set too high or was not working.
Recent events (2)
- · I (S) $1040
- · Z (S) $1600
1910.107 C02
- Issued
- Jun 9, 2016
- Abate by
- Jul 27, 2016
- Penalty
- Initial $2,000 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.107(c)(2): Open flame(s) or spark producing equipment, not separated by a partition, were located within 20 feet of spraying area(s): Knockdown Area: On, or about, March 24, 2016, Sherman Williams Silver Brite Aluminum paint, a Category 3 flammable liquid, was applied to parts being prepared for shipment with an air spraying. The spraying operation was 18 feet from a welding operation.
Recent events (2)
- · I (S) $1300
- · Z (S) $2000
1910.107 C09 I
- Issued
- Jun 9, 2016
- Abate by
- Jul 27, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(9)(i): 29 CFR 1910.107(c)(9)(i): All metal parts of piping systems conveying flammable or combustible liquids were not properly electrically grounded in an effective and permanent manner: Knockdown Area: On, or about, March 24, 2016, Sherman Williams Silver Brite Aluminum paint, a Category 3 flammable liquid, was applied to parts using a Husky air sprayer. The spray gun was not grounded back to the building surface.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.178 L01 I
- Issued
- Jun 9, 2016
- Abate by
- Jul 27, 2016
- Penalty
- Initial $1,600 · Current $1,040 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): Shop: On, or about, March 24, 2016, the company did not have a program to train forktruck operations regarding the safe use and handling of powered industrial trucks. Four employees were designated to use a sit-down forktruck.
Recent events (2)
- · I (S) $1040
- · Z (S) $1600
1910.212 A02
- Issued
- Jun 9, 2016
- Abate by
- Jul 27, 2016
- Penalty
- Initial $1,600 · Current $1,040 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Machine guard(s) on machine(s) were so installed that they offered accident hazards in themselves: Shop: On, or about, March 24, 2016, the barrier guard provided on the Perkins mechanical power press had sharp edges on the right side due to the unfinished expanded metal material used to construct the guard.
Recent events (2)
- · I (S) $1040
- · Z (S) $1600
1910.217 E01 I A
- Issued
- Jun 9, 2016
- Abate by
- Jul 27, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(e)(1)(i)(A): Periodic and regular inspections of each power press were not conducted to ensure that all of its parts, auxiliary equipment, and safeguards, including clutch/brake mechanism, antirepeat feature, and single-stroke mechanism, are in safe operating condition and adjustment: Shop: On, or about, March 24, 2016, the Perkins mechanical power press was not subject to periodic, documented inspections.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.217 E01 II A
- Issued
- Jun 9, 2016
- Abate by
- Jul 27, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(e)(1)(ii)(A): Inspections and tests of each press on a weekly basis were not being completed to determine the condition of the clutch/ brake mechanism, anti repeat feature and single stroke mechanism: Shop: On, or about, March 24, 2016, the Perkins mechanical power press was not checked weekly for proper function of the single stroke mechanism and the clutch/brake mechanism.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A03 II
- Issued
- Jun 9, 2016
- Abate by
- Nov 4, 2016
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): Shop: On, or about, March 24, 2016, the following machines were not provided with safeguarding: A. The barrier guard provided on the Pexto shear allowed entry to the blade area from under the guard. B. The barrier guard provided on the Accurshear 625010 allowed entry to the blade area from under the through the guard. C. The Accurpress 713012 press brake was not provided with point of operation safeguarding. D. The Bend-All press brake was not provided with point of operation safeguarding. E. The Verson press brake was not provided with point of operation safeguarding. F. The Niagara press brake was not provided with point of operation safeguarding. G. The barrier guard provided on the punching station for the Pirahna P50 Iron Worker was stuck in the raised position and the angle cutting station outfeed cover was secured in a raised position.
Recent events (2)
- · I (S) $1820
- · Z (S) $2800
1910.252 B02 III
- Issued
- Jun 9, 2016
- Abate by
- Jul 27, 2016
- Penalty
- Initial $1,200 · Current $780 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: Shop: On, or about, March 24, 2016, welding screens were not provided to protect employees walking and/or working along the main aisle of the shop from rays generated in the welding booth area.
Recent events (2)
- · I (S) $780
- · Z (S) $1200
1910.305 B01 II
- Issued
- Jun 9, 2016
- Abate by
- Jul 27, 2016
- Penalty
- Initial $1,600 · Current $1,040 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Shop: On, or about, March 26, 2016, the following electrical boxes had unused openings: A. Panel C-1: A breaker was missing at position 3. B. Exhaust fan box located next to Panel C-2: An open knockout below the toggle switches.
Recent events (2)
- · I (S) $1040
- · Z (S) $1600
1910.305 F01
- Issued
- Jun 9, 2016
- Abate by
- Jul 27, 2016
- Penalty
- Initial $1,200 · Current $780 Reduced
General-duty citation text
29 CFR 1910.305(f)(1): Conductors used for general wiring were not insulated: Shop: On, or about, March 24, 2016, the flexible cords provided for the foot pedal controls on the following machines were damaged: A. Bend-All press brake. B. Piranha iron worker.
Recent events (2)
- · I (S) $780
- · Z (S) $1200
1910.303 G01
- Issued
- Jun 9, 2016
- Abate by
- Jul 27, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Shop: On, or about, March 24, 2016, access to Panel PPA2 was totally blocked by pallets of material.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Tech-Air, Incorporated
View Tech-Air, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341356178.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.