BROOKSVILLE, FL —
OSHA Inspection: AIRDYNE AEROSPACE INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of AIRDYNE AEROSPACE INC. in 3160 PREMIER DRIVE, BROOKSVILLE, FL 34604 (NAICS 336413). OSHA activity number 341361517.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AIRDYNE AEROSPACE INC.
- Site address
- 3160 PREMIER DRIVE
- City
- BROOKSVILLE
- State
- FL
- ZIP
- 34604
- Mailing
- 3160 PREMIER DRIVE, BROOKSVILLE, FL 34604
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336413
- Employees
- 30
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.23 D01
- Issued
- Jun 3, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails: a) Building 3160 - The 40.25 inch high and 36 inch wide set of stairs to the C-130 mock-up had no rails, on or about March 31, 2016.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.39 B
- Issued
- Jun 3, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.39(b): A fire prevention was not in writing, kept in the workplace, and made available to employees for review: a) Buildings 3160 and 3184 - No plan was developed and the facility used flammable materials such as, but not limited to, acetone, polyurethane coatings and epoxy polyamide primer, on or about March 31, 2016.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.107 B05 IV
- Issued
- Jun 3, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a) Building 3160 - The spray booth used to spray flammable primers and coatings did not have sprinklers, on or about March 31, 2016.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.1026 L01
- Issued
- Jun 3, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.1026(l)(1): The employer did not ensure that all employees who were assigned to workplaces where there was exposure to chromium (VI) were provided with information and training as required by the Hazard Communication Standard 29 CFR 1910.1200: a) Building 3160, painting area - No training on the hazards of chromium (VI) was provided to painters, on or about March 31, 2016.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.38 B
- Issued
- Jun 3, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review: a) Buildings 3160 and 3184 - No plan was developed, on or about March 31, 2016.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C02 II
- Issued
- Jun 3, 2016
- Abate by
- Jul 8, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) Painting Area - No program was developed and respirator usage was voluntary for the painter, on or about March 31, 2016.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 E01
- Issued
- Jun 3, 2016
- Abate by
- Jul 8, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Painting Area - No medical evaluations were performed, on or about March 31, 2016.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 K
- Issued
- Jun 3, 2016
- Abate by
- Jul 8, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k): The employer did not provide the basic information on respirators in accordance with Appendix D of this section to employees who wear respirators when not required by this section or by the employer to do so: a) Paint Area - Appendix D was not provided to the painter who wore a half-face air purifying respirator on a voluntary basis, on or about March 31, 2016.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.212 B
- Issued
- Jun 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Buildings 3160 - DoAll bandsaw, was sitting on a wooden pallet, on or about March 31, 2016.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1026 D01
- Issued
- Jun 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): a) Painting Area - No exposure determination was made and spray painting was conducted using epoxy polyamide primer that contained 10.98% hexavalent chromium, on or about March 31, 2016.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Airdyne Aerospace INC.
View Airdyne Aerospace INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336413)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341361517.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.