Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: R.C. MOORE LUMBER COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of R.C. MOORE LUMBER COMPANY, INC. in 819 PLANING MILL STREET, CALDWELL, OH 43724 (NAICS 238160). OSHA activity number 341362242.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R.C. Moore Lumber Company, INC. for free Get an email when a new federal OSHA severe-injury report for R.C. Moore Lumber Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
819 PLANING MILL STREET
City
CALDWELL
State
OH
ZIP
43724
Mailing
819 PLANING MILL STREET, CALDWELL, OH 43724
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
15
Ownership type
Private (A)

3 citations on file for this inspection.

1926.501 B10

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 19, 2016
Abate by
Apr 29, 2016
Penalty
Initial $1,360 · Current $952 Reduced
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.  a. On or before March 29, 2016, where employees were installing roofing to the west side of the building, employees were not protected from falls of 9 feet, 10 inches, thereby being exposed to fall hazards.
Recent events (2)
  • · I (S) $952
  • · Z (S) $1360

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 19, 2016
Abate by
Apr 29, 2016
Penalty
Initial $1,360 · Current $952 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.   a. On or before March 29, 2016, where employees were using ladders to access the roof, the ladders did not extend at least 3 feet above the landing surface thereby exposing the employees to fall hazards.
Recent events (2)
  • · I (S) $952
  • · Z (S) $1360

1926.1053 B04

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 19, 2016
Abate by
Apr 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed.   a. On or before March 29, 2016, where employees were working on the roof of the building, step ladders were being used in the closed position to access the roof, thereby exposing the employees to fall hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View R.C. Moore Lumber Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341362242.