On , OSHA opened an unprogrammed Other safety inspection of PARLOR CITY DRYWALL & PAINTING in MICROTEL INN & SUITES, 400 PROSPECT STREET, BINGHAMTON, NY 13905 (NAICS 238310). OSHA activity number 341363133.

Watch Parlor City Drywall & Painting — free Get an email when a new federal OSHA severe-injury report for Parlor City Drywall & Painting is published. One employer, no account, unsubscribe in one click.
Site address
MICROTEL INN & SUITES, 400 PROSPECT STREET
City
BINGHAMTON
State
NY
ZIP
13905
Mailing
544 STATE STREET, BINGHAMTON, NY 13901
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
25
Ownership type
A

8 citations on file for this inspection.

1926.403 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:       a) Center of building, First floor corridor, on or about 3-29-16:  Employees were using a 4"x4" receptacle box that was not being used as designed or for its intended purpose (listed/labeled).       ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.404 B01 II

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:    a) Center of building, First floor corridor, on or about 3-29-16:  Employees were using a 4"x4" receptacle box to power various power tools and was not protected by a ground fault circuit interrupter (GFCI).     ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide:       a) Second to third floor stairway, on or about 3-29-16:  One employee was working on a scaffold platform that was 14 inches wide, exposing the employees to a fall hazard up to 13 feet 2 inches.       ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level:       a) Second to third floor stairway, on or about 3-29-16:  One employee was working on a scaffold platform without fall protection, exposing the employee to a fall hazard of 13 feet 2 inches.       ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.451 F03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:       a) Second to third floor stairway, on or about 3-29-16:  One employee was working on a scaffold system that was not inspected by a competent person for deficiencies.       ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:    a) Second to third floor stairway, on or about 3-29-16:  One employee was working on a scaffold system without safe access, exposing the employee to a fall hazard of 13 feet 2 inches.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:       a) Second to third floor stairway, on or about 3-29-16:  One employee was working on a scaffold system without the training necessary to recognize the hazards associated with scaffold work.       ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.452 N01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(n)(1): 29CFR 1926.452(n)(1): Scaffold platforms were placed higher than the second highest rung or step of the ladder supporting the platform:    a) Second to third floor stairway, on or about 3-29-16:  One employee was working on a scaffold system that was resting on the top of a ladder, exposing the employees to a fall hazard of 13 feet 2 inches.      ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM