Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. IMMIGRATION & CUSTOMS ENFORCEMENT (ICE), HOMELAND SECURITY INVESTIGATIONS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. IMMIGRATION & CUSTOMS ENFORCEMENT (ICE), HOMELAND SECURITY INVESTIGATIONS in 1000 2ND AVENUE SUITE 2300, SEATTLE, WA 98104 (NAICS 922190). OSHA activity number 341364321.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Immigration & Customs Enforcement (ICE), Homeland Security Investigations — free Get an email when a new federal OSHA severe-injury report for U.S. Immigration & Customs Enforcement (ICE), Homeland Security Investigations is published. One employer, no account, unsubscribe in one click.
Site address
1000 2ND AVENUE SUITE 2300
City
SEATTLE
State
WA
ZIP
98104
Mailing
1000 2ND AVENUE SUITE 2300, SEATTLE, WA 98104
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922190
Employees
110
Ownership type
D

5 citations on file for this inspection.

1910.303 B02

Serious Gravity 1 1 instance 109 exposed
Issued
May 27, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with  instructions included in the listing or labeling:   a) Floor 26 Cubicle, where two relocatable power taps were daisy chained and used to supply power to appliances including the Black and Decker refrigerator.
Recent events (1)
  • — Z (S) $0

1910.157 E02

Other-than-serious 5 instances 109 exposed
Issued
May 27, 2016
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:   a) Facility, fire extinguishers not inspected on a monthly basis included, but were not limited to:  1. Government Vehicles, where employees would be expected to fight incipient stage fires, records of inspection were not maintained for the Kidde fire extinguisher.  2. Floor 23, where employees would evacuate the building in the event of a fire, the Badger fire extinguisher located in the kitchen was equipped with a monthly inspection tag dated July 31, 2015.  3. Floor 24, where employees would evacuate the building in the event of a fire, the Badger fire extinguisher located in the office suite was equipped with a monthly inspection tag dated July 31, 2015.  4. Floor 26, where employees would evacuate the building in the event of a fire, the Sentry fire extinguisher located in the office suite was equipped with a monthly inspection tag dated July 31, 2015.  5. Floor 31, where employees would evacuate the building in the event of a fire, the Sentry fire extinguisher located in the kitchen was equipped with a monthly inspection tag dated January 8, 2015.
Recent events (1)
  • — Z (O) $0

1910.157 E03

Other-than-serious 1 instance 109 exposed
Issued
May 27, 2016
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3):  The employer did not assure that portable fire extinguishers were subjected to an annual maintenance check:   a) Government Vehicles, where employees would be expected to fight incipient stage fires, annual inspections were not conducted for fire extinguishers such as, but not limited to, Kidde fire extinguishers contained in the vehicle safety bags.
Recent events (1)
  • — Z (O) $0

1910.157 G02

Other-than-serious 1 instance 109 exposed
Issued
May 27, 2016
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting was not provided to all employees upon initial employment, and at least annually thereafter:   a) Government Vehicles, where employees would be expected to fight incipient stage fires, initial training was not provided.
Recent events (1)
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 109 exposed
Issued
May 27, 2016
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:   a) Floor 26 Kitchen, where the outlet located adjacent to the refrigerator was not equipped with a face plate.
Recent events (1)
  • — Z (O) $0

View U.S. Immigration & Customs Enforcement (ICE), Homeland Security Investigations's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341364321.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.