HOWE, TX —
OSHA Inspection: MAGNI-FAB SOUTHWEST COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MAGNI-FAB SOUTHWEST COMPANY, INC. in 811 N COLLINS FWY 1800 N. COLLINS FWY, HOWE, TX 75459 (NAICS 332312). OSHA activity number 341366391.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAGNI-FAB SOUTHWEST COMPANY, INC.
- Site address
- 811 N COLLINS FWY 1800 N. COLLINS FWY
- City
- HOWE
- State
- TX
- ZIP
- 75459
- Mailing
- 811 N COLLINS FWY P.O. BOX 578, HOWE, TX 75459
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 61
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.151 C
- Issued
- May 2, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.179 G02 III
- Issued
- May 2, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $1,785 · Current $1,071 Reduced
General-duty citation text
29 CFR 1910.179(g)(2)(iii): Guards for live parts were not substantial and so located that they could not be accidentally deformed so as to make contact with live parts: At the 1800 N. Collins, Howe, TX location in the production department, the employer did not ensure that the 7 1/2 ton crane pendant control electrical wiring was free from strain and internal conductors showing exposing employees to electrical shock hazards.
Recent events (2)
- — I (S) $1071
- — Z (S) $1785
1910.305 G01 IV A
- Issued
- May 2, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $1,785 · Current $1,071 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: At the 1800 N. Collins, Howe, TX location in the production bunk bed fabrication department, the employer used temporary flexible cords in lieu of permanent wiring to supply electrical power to electrical powered tools exposing employees to electrical shock and fire hazards.
Recent events (2)
- — I (S) $1071
- — Z (S) $1785
1910.305 G01 IV D
- Issued
- May 2, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces: At the 1800 N. Collins, Howe, TX location in the production department, the employer attached an electrical extension cord to the ceiling and suspended the extension cord to supply electrical power to power hand tools used in the bunk bed assembly department which exposed employees to electrical shock and fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Magni-Fab Southwest Company, INC.
View Magni-Fab Southwest Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341366391.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.