Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: ADCO BUILDERS CORP.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ADCO BUILDERS CORP. in 69 JAVA STREET, BROOKLYN, NY 11222 (NAICS 236116). OSHA activity number 341366664.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Adco Builders Corp. for free Get an email when a new federal OSHA severe-injury report for Adco Builders Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
ADCO BUILDERS CORP.
Site address
69 JAVA STREET
City
BROOKLYN
State
NY
ZIP
11222
Mailing
854 HUMBOLDT ST., BROOKLYN, NY 11222
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
1
Ownership type
Private (A)

6 citations on file for this inspection.

1926.405 A02 II E

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $1,600 · Current $900 Reduced
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage    Location: 69 Java,  Street Brooklyn NY 1st floor    On or about: March 31st 2016    a) Lamps used for general illumination in the basement were not protected with a cage or cover.
Recent events (2)
  • · I (S) $900
  • · Z (S) $1600

1926.701 B

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $2,800 · Current $1,800 Reduced
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement:    Location: 69 Java Street Brooklyn NY 1st floor    On or about: March 31st 2016    a)  Employees working and walking near and around exposed unprotected rebar.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $2800

1926.1052 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan.     Location: 69 Java Street Brooklyn NY staircase from the 1st floor to the basement.    On or about: March 31st 2016    a) Each Stairway and landing from the first floor to the basement were not temporarily filled with wood or other solid material.  Stairway used to access work area.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.1053 A24

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.1053(a)(24): The side rails of through or sidestep fixed ladders did not extend 42 inches (1.1 m) above the top of the access level or landing platform served by the ladder:    Location: 69 Java Street Brooklyn NY 1st floor    On or about: March 31st 2016     a) Employees used 10 foot ladder to access work area and the ladder did not extend 3 feet above the landing.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1926.403 I02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $2,000 · Current $1,900 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.    Location:  69 Java Street,  Brooklyn, NY 1st floor    On or about: March 31st 2016    a) Energized circuit breaker panel was not closed with a cover.  Employees walked and worked in and around the area of the energized panel.
Recent events (2)
  • · I (S) $1900
  • · Z (S) $2000

1926.404 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 1, 2016
Abate by
Aug 11, 2016
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.404(b)(1): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.    Location: 69 Java Street Brooklyn NY 1st floor    On or about: March 31st 2016    a) Employees were utilizing power tools and the cords were not provided with GFCI's.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341366664.