Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LSI-ADL TECHNOLOGY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of LSI-ADL TECHNOLOGY in 2727 SCIOTO PKWY, COLUMBUS, OH 43221 (NAICS 334412). OSHA activity number 341366987.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lsi-Adl Technology — free Get an email when a new federal OSHA severe-injury report for Lsi-Adl Technology is published. One employer, no account, unsubscribe in one click.
Establishment
LSI-ADL TECHNOLOGY
Site address
2727 SCIOTO PKWY
City
COLUMBUS
State
OH
ZIP
43221
Mailing
2727 SCIOTA PKWY, COLUMBUS, OH 43221
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334412
Employees
225
Ownership type
A

2 citations on file for this inspection.

1910.23 B01 I

Serious Gravity 10 1 instance 7 exposed
Issued
Jun 7, 2016
Abate by
Jul 10, 2016
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.23(b)(1): Every wall opening from which there is a drop of more than 4 feet shall be guarded by one of the following:  29 CFR 1910.23(b)(1)(i): Rail, roller, picket fence, half door, or equivalent barrier. Where there is exposure below to falling materials, a removable toe board or the equivalent shall also be provided. When the opening is not in use for handling materials, the guard shall be kept in position regardless of a door on the opening. In addition, a grab handle shall be provided on each side of the opening with its center approximately 4 feet above floor level and of standard strength and mounting.  a. In the cable area, appropriate guarding was not in place for employees working near the wall opening while unloading product from forklifts, exposing employees to a 12' 3" fall hazard.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.1025 L01 I

Other-than-serious 1 instance 15 exposed
Issued
Jun 7, 2016
Abate by
Jul 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(l)(1)(i): Each employer who has a workplace in which there is a potential exposure to airborne lead at any level shall inform employees of the content of Appendices A and B of this regulation.  a. At the workplace, employees performing the lead soldering operations did not receive training on the contents of Appendices A and B of the OSHA 1910.1025 lead regulation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341366987.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.