SALEM, NH —
OSHA Inspection: NORTH EAST FOAM SOLUTIONS INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of NORTH EAST FOAM SOLUTIONS INC. in 14 GARABEDIAN DR, SALEM, NH 03079 (NAICS 236220). OSHA activity number 341367449.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORTH EAST FOAM SOLUTIONS INC.
- Site address
- 14 GARABEDIAN DR
- City
- SALEM
- State
- NH
- ZIP
- 03079
- Mailing
- 39 EATON ROAD, DEDHAM, MA 02026
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 H02 I
- Issued
- Jul 13, 2016
- Abate by
- Jul 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): The employer did not ensure all respirators were stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals, and were packed or stored to prevent deformation of the facepiece and exhalation valve: Location: 15 Garabedian Drive Salem, NH: a. On or about April 1, 2016, employee respirators were being stored overnight in locations that did not protect them from contamination or damaging chemicals to include a location on top of a 55 gallon drum of Diphenylmethane-4,4'-diisocyanate (MDI).
Recent events (1)
- — Z (O) $0
1910.305 G02 III
- Issued
- Jul 13, 2016
- Abate by
- Jul 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. Location: 15 Garabedian Drive Salem, NH: a. On or about April 1, 2016, a cord connected to the Gardner Denver compressor was not provided with strain relief.
Recent events (1)
- — Z (O) $0
More inspections at North East Foam Solutions INC.