DEER PARK, TX —
OSHA Inspection: LEADER GASKET TECHNOLOGIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LEADER GASKET TECHNOLOGIES, INC. in 905 W. 13TH STREET, DEER PARK, TX 77536 (NAICS 339991). OSHA activity number 341367993.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEADER GASKET TECHNOLOGIES, INC.
- Site address
- 905 W. 13TH STREET
- City
- DEER PARK
- State
- TX
- ZIP
- 77536
- Mailing
- 905 W. 13TH STREET, DEER PARK, TX 77536
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339991
- Employees
- 60
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Aug 29, 2016
- Abate by
- Sep 6, 2016
- Penalty
- Initial $11,224 · Current $8,980 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) At the worksite where energy control procedures had not been developed, documented and utilized for the 3-station hydraulic press.
Recent events (3)
- — F (O) $8980
- — C (S) $11224
- — Z (S) $11224
1910.212 A01
- Issued
- Aug 29, 2016
- Abate by
- Oct 3, 2016
- Penalty
- Initial $11,224 · Current $8,980 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) At the worksite, where the rear port of the 3-stage gasket corrugation press was not guarded, exposing employees to a rotating parts.
Recent events (3)
- — F (O) $8980
- — C (S) $11224
- — Z (S) $11224
1910.147 C06 II
- Issued
- Aug 29, 2016
- Abate by
- Sep 12, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) At the worksite where the employer did not certify that periodic inspections of the energy control procedures had been performed.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Leader Gasket Technologies, INC.
View Leader Gasket Technologies, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339991)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341367993.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.