Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: EJ FRAMING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EJ FRAMING in 8293 MOSS CIRCLE, ARVADA, CO 80007 (NAICS 238130). OSHA activity number 341378438.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch EJ Framing for free Get an email when a new federal OSHA severe-injury report for EJ Framing is published. One employer, no account, unsubscribe in one click.
Establishment
EJ FRAMING
Site address
8293 MOSS CIRCLE
City
ARVADA
State
CO
ZIP
80007
Mailing
7470 DAKIN ST. UNIT 305, DENVER, CO 80221
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

4 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 4, 2016
Abate by
Aug 23, 2016
Penalty
Initial $1,604 · Current $800 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    (a) On or about April 6, 2016, and at times prior, the employer did not ensure that employees operating a powered industrial vehicle were properly trained.      Abatement note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $800
  • · Z (S) $1604

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 4, 2016
Abate by
Aug 12, 2016
Penalty
Initial $1,604 · Current $800 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     (a) On or about April 6, 2016, and at times prior, the employer did not ensure that employees installing a truss on a home under construction were protected from falls greater than 6 feet.      Abatement note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $800
  • · Z (S) $1604

1926.602 C01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 4, 2016
Abate by
Aug 12, 2016
Penalty
Initial $1,604 · Current $800 Reduced
29 CFR 1926.602(c)(1)(ii): Modifications or additions which affect the capacity or safe operation of the equipment were made without the manufacturer's written approval:    (a) On or about April 6, 2016, and at times prior, the employer made modifications to a powered industrial truck without manufacturer approval by attaching a 2x6 to the forks in order to lift a truss from the ground.      Abatement note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $800
  • · Z (S) $1604

1926.1053 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 4, 2016
Abate by
Aug 16, 2016
Penalty
Initial $1,604 · Current $1,400 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    (a) On or about April 7, and at times prior, the employer did not ensure that ladders used to access elevated work surfaces were extended at least 3 feet above the surface.      Abatement note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $1400
  • · Z (S) $1604

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341378438.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.