BRISTOL, PA ·
OSHA Inspection: ACTION MANUFACTURING COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ACTION MANUFACTURING COMPANY in 190 RITTENHOUSE CIRCLE, BRISTOL, PA 19007 (NAICS 332993). OSHA activity number 341379923.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACTION MANUFACTURING COMPANY
- Site address
- 190 RITTENHOUSE CIRCLE
- City
- BRISTOL
- State
- PA
- ZIP
- 19007
- Mailing
- 190 RITTENHOUSE CIRCLE, BRISTOL, PA 19007
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332993
- Employees
- 175
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.305 B01 II
- Issued
- Jun 30, 2016
- Penalty
- Initial $3,825 · Current $3,825
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Action Manufacturing - On or about April 6, 2016 four unused openings in a circuit breaker panel box were not effectively closed.
Recent events (2)
- · I (S) $3825
- · Z (S) $3825
1910.133 A03
- Issued
- Jun 30, 2016
- Abate by
- Jul 16, 2016
- Penalty
- Initial $3,060 · Current $3,137
General-duty citation text
29 CFR 1910.133(a)(3): The employer did not ensure that each affected employee who wore prescription lenses while engaged in operations that involved eye hazards wore eye protection that incorporated the prescription in its design, or wore eye protection that could be worn over the prescription lenses without disturbing the proper position of the prescription lenses or the protective lenses. a) Action Manufacturing - On or about April 6, 2016 an employee was cleaning parts machined on a chucking machine while wearing regular prescription glasses without side shields. a) Action Manufacturing - On or about April 26, 2016 an employee was cleaning parts machined on a chucking machine while wearing regular prescription glasses with detachable side shields.
Recent events (2)
- · I (S) $3137
- · Z (S) $3060
1910.242 B
- Issued
- Jun 30, 2016
- Abate by
- Jul 16, 2016
- Penalty
- Initial $3,060 · Current $0 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. and effective chip guarding and personal protective equipment was not used. a) Action Manufacturing - On or about April 6, 2016 compressed air for cleaning was not reduced to 30 PSI while an employee was cleaning parts machined on a chucking machine.
Recent events (2)
- · I (S) $0
- · Z (S) $3060
1910.147 C04 I
- Issued
- Jun 30, 2016
- Abate by
- Sep 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Action Manufacturing, CNC Secondary Department - On or about April 6, 2016 Procedures were not developed, documented and utilized for the control of potentially hazardous energy for a Star Micronics Company Model SR-20R CNC Screw machine. b) Action Manufacturing, CNC Secondary Department - On or about April 6, 2016 Procedures were not developed, documented and utilized for the control of potentially hazardous energy for New Britain Model 657 Multi Spindle Automatic Chucking Machines.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.304 F01 VIII
- Issued
- Jun 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD." a) Action Manufacturing - On or about April 6, 2016 five circuit breakers used on a daily basis as switches for fluorescent lighting were not listed and marked "SWD."
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Action Manufacturing Company
View Action Manufacturing Company's full OSHA safety record →
More inspections in this industry (NAICS 332993)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341379923.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.