SAINT CHARLES, IL —
OSHA Inspection: ACE ROOFING SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ACE ROOFING SERVICES, INC. in 412 STATE STREET, SAINT CHARLES, IL 60174 (NAICS 238160). OSHA activity number 341379998.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACE ROOFING SERVICES, INC.
- Site address
- 412 STATE STREET
- City
- SAINT CHARLES
- State
- IL
- ZIP
- 60174
- Mailing
- 6N 449 SHADY LANE, SAINT CHARLES, IL 60174
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.100 A
- Issued
- May 10, 2016
- Abate by
- May 20, 2016
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: On or about April 5, 2016, at the subject job site - Employees working below residential roofing operations were not wearing hard hats to protect against falling material and debris. Employees were exposed to struck-by hazards. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.102 A01
- Issued
- May 10, 2016
- Abate by
- May 20, 2016
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: On or about April 5, 2016, at the subject job site - Employees using pneumatic nail guns did not wear eye protection (safety glasses), thereby exposing employees to eye injuries from flying debris and broken nails. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1926.501 B13
- Issued
- May 10, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about April 5, 2016, at the subject job site - Employees engaged in residential roofing operations 10 feet to 13 feet above the ground were not protected from falling off the edge of the roof, thereby exposing employees to fall hazards. There is no abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1053 B01
- Issued
- May 10, 2016
- Penalty
- Initial $1,700 · Current $850 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about April 5, 2016, at the subject worksite - Three ladders were used to gain access to the roof of the house that did not extend at least three (3) feet above the landing. Employees were exposed to falling approximately 10 feet to 13 feet to the ground below while mounting and dismounting the ladder. No abatement information is required for this item.
Recent events (2)
- — I (S) $850
- — Z (S) $1700
More inspections at ACE Roofing Services, INC.
View ACE Roofing Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341379998.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.