Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE QUIKRETE COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE QUIKRETE COMPANY, INC. in 200 HORD STREET, HARAHAN, LA 70123 (NAICS 327390). OSHA activity number 341380319.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Quikrete Company, INC. — free Get an email when a new federal OSHA severe-injury report for The Quikrete Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
200 HORD STREET
City
HARAHAN
State
LA
ZIP
70123
Mailing
200 HORD STREET, HARAHAN, LA 70123
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
49
Ownership type
A

2 citations on file for this inspection.

1910.147 C06 I

Other-than-serious 5 instances 2 exposed
Issued
Apr 25, 2016
Abate by
May 8, 2016
Penalty
Initial $7,000 · Current $5,000 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    On or about April 6, 2016, at the Quikrete Company, Inc., the employer failed to ensure that a periodic inspection of energy control procedures was performed. Employees conducted LO/TO procedures at least three to four times per week.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $7000

1910.147 C06 II

Other-than-serious 4 instances 2 exposed
Issued
Apr 25, 2016
Abate by
May 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:    On or about April 6, 2016, at the Quikrete Company, Inc. Harahan, LA location the employer failed to certify that a periodic inspection of the energy control procedures were performed on the:    1) Packers/kickers on the Q-line  2) Semi-Automatic Palletizer on the Q1-line  3) Automatic Stretch Wrap in the plant  4) Compressors on the warehouse
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View The Quikrete Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341380319.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.