HARAHAN, LA —
OSHA Inspection: THE QUIKRETE COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of THE QUIKRETE COMPANY, INC. in 200 HORD STREET, HARAHAN, LA 70123 (NAICS 327390). OSHA activity number 341380319.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE QUIKRETE COMPANY, INC.
- Site address
- 200 HORD STREET
- City
- HARAHAN
- State
- LA
- ZIP
- 70123
- Mailing
- 200 HORD STREET, HARAHAN, LA 70123
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 49
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C06 I
- Issued
- Apr 25, 2016
- Abate by
- May 8, 2016
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about April 6, 2016, at the Quikrete Company, Inc., the employer failed to ensure that a periodic inspection of energy control procedures was performed. Employees conducted LO/TO procedures at least three to four times per week.
Recent events (2)
- — I (O) $5000
- — Z (S) $7000
1910.147 C06 II
- Issued
- Apr 25, 2016
- Abate by
- May 8, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: On or about April 6, 2016, at the Quikrete Company, Inc. Harahan, LA location the employer failed to certify that a periodic inspection of the energy control procedures were performed on the: 1) Packers/kickers on the Q-line 2) Semi-Automatic Palletizer on the Q1-line 3) Automatic Stretch Wrap in the plant 4) Compressors on the warehouse
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at The Quikrete Company, INC.
View The Quikrete Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327390)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341380319.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.