CAPE GIRARDEAU, MO —
OSHA Inspection: SOUTHEAST FABRICATING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SOUTHEAST FABRICATING INC. in 2086 SOUTHERN EXPRESSWAY, CAPE GIRARDEAU, MO 63701 (NAICS 332312). OSHA activity number 341380483.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOUTHEAST FABRICATING INC.
- Site address
- 2086 SOUTHERN EXPRESSWAY
- City
- CAPE GIRARDEAU
- State
- MO
- ZIP
- 63701
- Mailing
- 2086 SOUTHERN EXPRESSWAY, CAPE GIRARDEAU, MO 63701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 17
- Ownership type
- A
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 19, 2016
- Abate by
- Jun 6, 2016
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employee(s) in that employee(s) were exposed to the hazard of being caught-in: Inside of the Fabrication Shop, employee(s) were exposed to an amputation/laceration hazard due to a possible machine process malfunction on the following equipment: a/ American Standard 300T Press Brake. One method of abatement to correct this apparent hazard is to install emergency stop devices as required by ANSI B11.3-2002, paragraph 6.1.3.1. DISCLAIMER: a/ The employer is not limited to the abatement method(s) suggested by OSHA. b/ The employer is responsible for selecting and implementing an effective abatement method.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
5(a)(1)
- Issued
- Apr 19, 2016
- Abate by
- Jun 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employee(s) in that employee(s) were exposed to the hazard of being caught-in: Inside of the Fabrication Shop, employee(s) were exposed to an amputation/laceration hazard due to a possible machine process malfunction on the following equipment: a/ Wysong Shear, m/n unknown, s/n unknown. One method of abatement to correct this apparent hazard is to install emergency stop devices as required by ANSI B11.4-2003, paragraph 6.2.4. DISCLAIMER: a/ The employer is not limited to the abatement method(s) suggested by OSHA. b/ The employer is responsible for selecting and implementing an effective abatement method.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.133 A01
- Issued
- Apr 19, 2016
- Abate by
- Jun 6, 2016
- Penalty
- Initial $2,800 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a/ Inside of the Fabrication Shop, employee(s) using machines such as the Dewalt Hand Held Grinder, m/n D28433, were not provided with suitable eye and face protection. These employees would hand grind steel stock and experience serious injuries to their eyes from flying particles that resulted in multiple entries on the OSHA 300 Logs from 2013 to the present.
Recent events (2)
- — I (S) $2300
- — Z (S) $2800
1910.135 A01
- Issued
- Apr 19, 2016
- Abate by
- Jun 6, 2016
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wore a protective helmet when working in areas where there was a potential for injury to the head from falling objects: a/ Inside of the Fabrication Shop, employee(s) operating the Shaw-Box 5T Overhead Crane with suspended loads were not provided with suitable head protection.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.138 A
- Issued
- Apr 19, 2016
- Abate by
- Jun 6, 2016
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.138(a): Employers did not select and require employees to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes: a/ Inside of the Fabrication Shop, operator(s) of the Nissan Fork Truck, m/n 80, were not provided with suitable hand protection when changing out the LPG cylinder.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.147 C04 I
- Issued
- Apr 19, 2016
- Abate by
- Jun 6, 2016
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section: Inside of the Fabrication Shop, specific procedures were not developed, documented, or utilized for the following machinery: a/ Wysong Shear, m/n unknown, s/n unknown, 240 volts, 90 p.s.i. air, and gravity. b/ American Standard 300T Press Brake, 240 volts, hydraulics, and gravity.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.147 C05 I
- Issued
- Apr 19, 2016
- Abate by
- Jun 6, 2016
- Penalty
- Initial $2,000 · Current $500 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: Inside of the Fabrication Shop, specific lockout devices were not provided or utilized for the following machinery: a/ Wysong Shear, m/n unknown, s/n unknown, 240 volts, 90 p.s.i. air, and gravity. b/ American Standard 300T Press Brake, 240 volts, hydraulics, and gravity.
Recent events (2)
- — I (S) $500
- — Z (S) $2000
1910.212 A01
- Issued
- Apr 19, 2016
- Abate by
- Jun 6, 2016
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Inside of the Fabrication Shop, the rotating parts belonging to the following machines were unguarded: a/ William C. Johnson & Son Drill Press, m/n unknown, s/n unknown. b/ Powermatic Drilling Machine, m/n 1150, s/n 815V859.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1910.212 A03 II
- Issued
- Apr 19, 2016
- Abate by
- Jun 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a/ Inside of the Fabrication Shop, the P.O.O. belonging the the American Standard 300T Press Brake, m/n unknown, s/n unknown, was unguarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Apr 19, 2016
- Abate by
- Jun 6, 2016
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made: a/ Inside of the Fabrication Shop, the outer insulation belonging to a flexible cord supplying electrical current to the guarded foot pedal attached to the American Standard 300T Press Brake, m/n unknown, s/n unknown, was missing.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
More inspections at Southeast Fabricating INC.