SURFSIDE, FL —
OSHA Inspection: BBB BIG BEAR BUILDERS INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BBB BIG BEAR BUILDERS INC. in 9011 COLLINS AVENUE, SURFSIDE, FL 33154 (NAICS 238140). OSHA activity number 341381887.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BBB BIG BEAR BUILDERS INC.
- Site address
- 9011 COLLINS AVENUE
- City
- SURFSIDE
- State
- FL
- ZIP
- 33154
- Mailing
- 14073 SW 168 LANE, MIAMI, FL 33177
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 26
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 D01
- Issued
- Jul 19, 2016
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
29 CFR 1926.451(d)(1): All suspension scaffold support devices, such as outrigger beams, cornice hooks, parapet clamps, and similar devices, did not rest on surfaces capable of supporting at least 4 times the load imposed on them by the scaffold operating at the rated load of the hoist (or at least 1.5 times the load imposed on them by the scaffold at the stall capacity of the hoist, whichever is greater): On or about April 4, 2016, at the above addressed jobsite, two employees were operating a suspension scaffold to apply stucco, for which the tiebacks anchors were not capable of supporting the greater of; at least 4 times the load imposed on them by the scaffold operating at the rated load of the hoist (or at least 1.5 times the load imposed on them by the scaffold at the stall capacity of the hoist, whichever is greater), which resulted in the failure of one of the two tieback anchors, and subsequent fall of the scaffold and both of the employees from between the 11th and 12th floor of the building.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
1926.451 F03
- Issued
- Jul 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about April 4, 2016, at the above addressed jobsite, two employees were operating a suspension scaffold which had not been inspected for visible defects by a competent person before each work shift, and for which the scaffold system was observed to have safety deficiencies; such as but not limited to: a missing front guard rail, and tieback components not capable of supporting the required load, which resulted in the failure of one of the two tieback anchors, and subsequent fall of the scaffold and both of the employees from between the 11th and 12th floor of the building.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 II
- Issued
- Jul 19, 2016
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system: On or about April 4, 2016, at the above addressed jobsite, two employees were operating a suspension scaffold, for which the front guardrail had been removed/not installed, therefore exposing the employees to a fall hazard.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
1926.451 F07
- Issued
- Jul 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: On or about April 4, 2016, at the above addressed jobsite, two employees were operating a suspension scaffold which had been erected, moved, dismantled and altered, while not under the supervision and direction of a competent person, and for which the scaffold system was observed to have safety deficiencies; such as but not limited to: a missing front guard rail, and tieback components not capable of supporting the required load, which resulted in the failure of one of the two tieback anchors, and subsequent fall of the scaffold and both of the employees from between the 11th and 12th floor of the building.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at BBB BIG Bear Builders INC.
View BBB BIG Bear Builders INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341381887.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.