Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: C & J ACOUSTICAL CEILINGS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C & J ACOUSTICAL CEILINGS in 4935 MONTECILLO, EL PASO, TX 79912 (NAICS 238130). OSHA activity number 341384030.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C & J Acoustical Ceilings for free Get an email when a new federal OSHA severe-injury report for C & J Acoustical Ceilings is published. One employer, no account, unsubscribe in one click.
Site address
4935 MONTECILLO
City
EL PASO
State
TX
ZIP
79912
Mailing
P.O. BOX 71233, EL PASO, TX 79917
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 27, 2016
Abate by
Jul 8, 2016
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  On or about April 7, 2016, and at times prior thereto, employees were framing the outside wall on the second floor of a commercial construction.  Employees were not provided with any type of fall protection, they were exposed to a fall of over 6 feet to the ground below.
Recent events (1)
  • · Z (S) $1600

1926.503 A02

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 27, 2016
Abate by
Jul 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii)  On or about April 7, 2015, and at times prior thereto, the employer did not assure employees had received training on fall hazards prior to having them work at height's over 6 feet above the ground below.
Recent events (1)
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341384030.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.