MONROE TOWNSHIP, NJ ·
OSHA Inspection: NARO CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NARO CONSTRUCTION LLC in 15 BRENTWOOD PLACE, MONROE TOWNSHIP, NJ 08831 (NAICS 238140). OSHA activity number 341387306.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NARO CONSTRUCTION LLC
- Site address
- 15 BRENTWOOD PLACE
- City
- MONROE TOWNSHIP
- State
- NJ
- ZIP
- 08831
- Mailing
- 143 CLEARVIEW AVE, HUNTINGDON VALLEY, PA 19006
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1926.451 F07
- Issued
- May 27, 2016
- Abate by
- Jun 6, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) 15 Brentwood Place, Monroe Township, NJ: The employer did not ensure that the fabricated metal frame scaffold had been erected uner the supervision of a competent person. This hazard was observed on 4/8/2016.
Recent events (1)
- · Z (S) $2800
1926.451 B01
- Issued
- May 27, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) 15 Brentwood Place, Monroe Township, NJ: The third and fourth working platforms of the fabricated metal frame scaffold were not fully planked or decked. This hazard was observed on 4/8/18.
Recent events (1)
- · Z (S) $0
1926.451 C01
- Issued
- May 27, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. a) 15 Brentwood Place, Monroe Township, NJ: The four tier fabricated metal frame scaffold with a base width of approximatley 5 feet and a height of 26 feet 5 inches was not braced or tied to prevent tipping. This hazard was observed on 4/8/2016.
Recent events (1)
- · Z (S) $0
1926.451 E01
- Issued
- May 27, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. a) 15 Brentwood Place, Monroe Township, NJ: A ladder or other safe means of access was not provided and used by employees who were working on the third and fourth levels of a fabricated metal frame scaffold. This hazard was observed on 4/8/16.
Recent events (1)
- · Z (S) $0
1926.451 G01 VII
- Issued
- May 27, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) 15 Brentwood Place, Monroe Township, NJ: Employees who were working from a fabricated metal frame scaffold, on platforms approximately 20 feet above the ground, were not protected from falling by an adequate fall protection system. This hazard was observed on 4/8/16.
Recent events (1)
- · Z (S) $0
1926.452 C02
- Issued
- May 27, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a: 15 Brentwood Place, Monroe Township, NJ: The four tier fabricated metal frame scaffold was not equipped with adequate cross bracing on both sides. This hazard was observed on 4/8/16.
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 238140)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341387306.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.