OSHA Inspection: TACURI CONSTRUCTION, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TACURI CONSTRUCTION, LLC in 95 COLES ST, JERSEY CITY, NJ 07302 (NAICS 238140). OSHA activity number 341387728.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tacuri Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Tacuri Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
95 COLES ST
City
JERSEY CITY
State
NJ
ZIP
07302
Mailing
74 HAWTHORNE AVENUE, NEWARK, NJ 07112
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
15
Ownership type
A

5 citations on file for this inspection.

1926.300 B04 II

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 1, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.300(b)(4)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.  95 Coles St., Jersey City, NJ.  Employees were observed utilizing a chop saw with a by-passed guard that didn't allow the guard device to be fully functional as its intended purpose for protecting employees from being injured at the point of operation, there-by exposing employees to amputation hazards.   Violation occurred on or about 03/29/2016
Recent events (1)
  • — Z (S) $2800

1926.404 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 1, 2016
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.404(b)(1)(ii): Ground-fault circuit interrupters. All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection.    a.) 95 Coles St., Jersey City, NJ.   Employees were observed using receptacle outlets that were not approved or deemed acceptable as a Ground-fault circuit interrupters under according to 29 CFR 1926.449(a); there-by exposing employees to electrical hazards.       Violation occurred on or about 3/29/2016.
Recent events (1)
  • — Z (S) $2000

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 1, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.  a.) 95 Coles St., Jersey City, NJ.  Employees were observed working on the 3rd level of a supported scaffold without adequate fall protection, there-by exposing employees to potential fall hazards approximately 25 ft. to the ground level or to the next lower level.    Violation occurred on or about 06/29/2016.
Recent events (1)
  • — Z (S) $2800

1926.501 B02 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 1, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(2)(i): Each employee who is constructing a leading edge 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, or personal fall arrest systems.    a.) 95 Coles St., Jersey City, NJ.  It was learned that Employees were engaged in leading edge work that wasn't provided with a adequate fall arrest system to protect employees from being exposed to fall hazards approximately 10ft above the ground level below.    Violation occurred on or about 03/29/2016.
Recent events (1)
  • — Z (S) $2800

1926.451 E09 IV

Repeat Gravity 10 1 instance 2 exposed
Issued
Jul 1, 2016
Penalty
Initial $5,600 · Current $5,600
29 CFR 1926.451(e)(9)(iv): Cross braces on tubular welded frame scaffolds shall not be used as a means of access or egress.  a.) 95 Coles St., Jersey City, NJ.    Employees were observed utilizing cross braces on scaffold as their sole means of access to upper levels and egress to lower levels, there-by exposing employees to fall hazards from approximately 2-3 stories high above the ground surface.     Violation occurred on or about 3/29/2016.  Tacuri Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(e)(9)(iv), which was contained in OSHA inspection number 1088342, citation number, 1 item number 1 and was affirmed as a final order on 11/18/2015, with respect to a workplace located at 766 Main St., Paterson NJ
Recent events (1)
  • — Z (R) $5600

View Tacuri Construction, LLC's full OSHA safety record →