CAMP HILL, PA —
OSHA Inspection: WEIDNER CONSTRUCTION SERVICES, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of WEIDNER CONSTRUCTION SERVICES, LLC in CAPITAL CITY MALL 3506 CAPITAL CITY MALL DRIVE, CAMP HILL, PA 17011 (NAICS 236220). OSHA activity number 341391589.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WEIDNER CONSTRUCTION SERVICES, LLC
- Site address
- CAPITAL CITY MALL 3506 CAPITAL CITY MALL DRIVE
- City
- CAMP HILL
- State
- PA
- ZIP
- 17011
- Mailing
- 5060 RITTER ROAD, SUITE B1, MECHANICSBURG, PA 17055
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.55 A
- Issued
- Jun 15, 2016
- Abate by
- Jul 12, 2016
- Penalty
- Initial $1,700 · Current $1,700
C730
General-duty citation text
29 CFR 1926.55(a): Employee(s) were exposed to material(s) at concentrations above those specified in the Threshold Limit Values of Airborne Contaminants for 1970 of the American Conference of Governmental Industrial Hygienists: (a) Weidner Construction Services, LLC - The employee operating the Diamond Products Model CC1213HS propane powered concrete saw, Serial Number 140582, to cut slots in the concrete floor was exposed to an Eight Hour Time Weighted Average (TWA8) of carbon monoxide at 102 Parts Per Million (PPM). This exposure was approximately 2 times the Permissible Exposure Limit (PEL) of 50 PPM. The exposure was calculated from the employee's blood carboxyhemoglobin level on April 12, 2016.
Recent events (2)
- — I (O) $1700
- — Z (S) $1700
1926.55 B
- Issued
- Jun 15, 2016
- Abate by
- Jul 12, 2016
- Penalty
- Initial $0 · Current $0
C730
General-duty citation text
29 CFR 1926.55(b): Feasible administrative or engineering controls were not implemented to reduce employee exposure(s): (a) Weidner Construction Services, LLC - The employer did not ensure that the ventilation used to control the carbon monoxide fumes from the Diamond Products Model CC1213HS propane powered concrete saw, Serial Number 140582, being used to cut slots in the concrete floor was adequate thus, exposed the employee to carbon monoxide at 102 Parts Per Million (PPM), on or about April 12, 2016. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Weidner Construction Services, LLC
View Weidner Construction Services, LLC's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341391589.