SUAMICO, WI ·
OSHA Inspection: C. J. BURKEL & SONS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of C. J. BURKEL & SONS, LLC in 2472 ST. PATS DR., SUAMICO, WI 54313 (NAICS 238910). OSHA activity number 341392918.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C. J. BURKEL & SONS, LLC
- Site address
- 2472 ST. PATS DR.
- City
- SUAMICO
- State
- WI
- ZIP
- 54313
- Mailing
- 4315 N. OVERLAND RD., ONEIDA, WI 54155
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 2
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.651 K02
- Issued
- May 12, 2016
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety. On or about April 12, 2016, a competent person onsite did not remove an employee from a trench with a depth of approximately 7' deep that did not have adequate sloping for trench protection.
Recent events (2)
- · I (S) $2000
- · Z (S) $2800
1926.652 A01
- Issued
- May 12, 2016
- Penalty
- Initial $7,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): On or about April 12, 2016, an employee was injured as the result of a cave-in while installing storm drain in a trench with an approximate depth of 7' without adequate trench protection. The trench was vertically cut in Type C soil with no sloping or protective system.
Recent events (2)
- · I (S) $2000
- · Z (S) $7000
More inspections in this industry (NAICS 238910)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341392918.