Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: AIRCO PLATING COMPANY, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of AIRCO PLATING COMPANY, INC. in 3650 NW 46TH ST, MIAMI, FL 33142 (NAICS 332813). OSHA activity number 341394575.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Airco Plating Company, INC. — free Get an email when a new federal OSHA severe-injury report for Airco Plating Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3650 NW 46TH ST
City
MIAMI
State
FL
ZIP
33142
Mailing
3650 NW 46TH ST, MIAMI, FL 33142
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
25
Ownership type
A

8 citations on file for this inspection.

1910.124 G02

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 7, 2016
Penalty
Initial $2,800 · Current $2,000 Reduced

Hazardous substances 0686

29 CFR 1910.124(g)(2): Employees who  worked with liquids that could burn, irritate, or otherwise harm their skin were not provided with an emergency shower and eye-wash station close to the dipping and coating operation:    On or about 4/13/16, at the above address jobsite, the employer did not provide an emergency shower near dip tanks where employees would be exposed to corrosive chemicals such as, but not limited to chromic acid.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1910.124 H04

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 7, 2016
Abate by
Jul 11, 2016
Penalty
Initial $1,700 · Current $1,000 Reduced

Hazardous substances 0686

29 CFR 1910.124(h)(4): Employees working with chromic acid were not provided with periodic examinations of their exposed body parts, especially their nostrils:    On or about 4/13/16, at the above address jobsite, employees working with chromic acid were not provided a medical examination as required by the standard.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1700

1910.133 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 7, 2016
Abate by
Jul 1, 2016
Penalty
Initial $2,800 · Current $1,600 Reduced

Hazardous substances 0686

29 CFR 1910.133(a)(1): Protective face equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:    On or about 04/13/16, at the above address jobsite, the employer did not provide face protection near dip tanks where employees would be exposed to corrosive chemicals such as, but not limited to chromic acid.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2800

1910.1027 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 7, 2016
Abate by
Jul 30, 2016
Penalty
Initial $1,700 · Current $1,000 Reduced

Hazardous substances C142

29 CFR 1910.1027(g)(2)(i): Where respiratory protection was required for protection against cadmium, the employer did not institute a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) (except (d)(1)(iii)), and (f) through (m) for each employee required by 29 CFR 1910.1027 to use a respirator:    On or about 4/13/16, at the above address jobsite, the employer did not implement a respirator program for employees over-exposed to the cadmium action level.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1700

1910.1027 L01 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 7, 2016
Abate by
Jul 30, 2016
Penalty
Initial $2,800 · Current $1,600 Reduced

Hazardous substances C142

29 CFR 1910.1027(l)(1)(i)(A): The employer did not institute a medical surveillance program for all employees who were or potentially were exposed to cadmium at or above the action level on 30 or more days per year (twelve consecutive months):    On or about 4/13/16, at the above address jobsite, the employer did not implement a medical surveillance program for employees over-exposed to the cadmium action level.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2800

1910.1027 I02 IV

Other-than-serious 1 instance 1 exposed
Issued
Jun 7, 2016
Abate by
Jul 25, 2016
Penalty
Initial $0 · Current $0

Hazardous substances C141

29 CFR 1910.1027(i)(2)(iv): The employer did not ensure that bags or containers of contaminated protective clothing and equipment that were to be taken out of change rooms or the workplace for laundering, cleaning, maintenance or disposal bore labels in accordance with 29 CFR 1910.1027(m):  On or about 4/13/16, at the above address jobsite, the employer had not labeled the bags of clothing taken by a laundering contractor. The bags of clothing were contaminated with cadmium from the electroplating process conducted at the facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 25 exposed
Issued
Jun 7, 2016
Abate by
Jul 11, 2016
Penalty
Initial $340 · Current $0 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):     On or about 4/13/16, at the above address jobsite, the employer did not have a written hazard communication program for all chemicals used in the electroplating processes performed at the facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $340

1910.1200 F06 II

Other-than-serious 1 instance 1 exposed
Issued
Jun 7, 2016
Abate by
Jul 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:  On or about 4/13/16, at the above address jobsite, the employer did not label several dip tanks used in the electroplating processes performed at the facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Airco Plating Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341394575.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.