Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: HOT TOPIC, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HOT TOPIC, INC. in 3333 BUFORD DRIVE NE #1110, BUFORD, GA 30519 (NAICS 448140). OSHA activity number 341398519.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HOT Topic, INC. for free Get an email when a new federal OSHA severe-injury report for HOT Topic, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
HOT TOPIC, INC.
Site address
3333 BUFORD DRIVE NE #1110
City
BUFORD
State
GA
ZIP
30519
Mailing
3333 BUFORD DR NE #1110, BUFORD, GA 30519
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
448140
Employees
12
Ownership type
Private (A)

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 12 exposed
Issued
May 13, 2016
Abate by
May 25, 2016
Penalty
Initial $7,000 · Current $4,900 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:  On or about 4/14/2016 in the store room;   a. employees were exposed to fall hazards above 9 feet (113") where the ladders did not extend 3 feet above the landing; employees entering the overhead storage loft above the entrance to the back room to store or remove materials such as but not limited to hardware and products for sale, were required to step onto the top step of the 7 foot portable Werner ladders and negotiate 22 inches to the landing;  b. employees were exposed to fall hazards above 9 feet (103") where the ladders did not extend 3 feet above the landing; employees entering the overhead storage loft above the restroom to store or remove materials such as but not limited to hardware and products for sale, were required to step onto the top step of the 7 foot portable Werner ladders and negotiate 12 inches to the landing.
Recent events (2)
  • · I (S) $4900
  • · Z (S) $7000

1910.22 D01

Serious Gravity 5 2 instances 12 exposed
Issued
May 13, 2016
Abate by
Jun 8, 2016
Penalty
Initial $5,000 · Current $3,492 Reduced
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:  On or about 4/14/2016 in the storage room: employees placing and removing materials such as but not limited to hardware and retail products into the loft areas are exposed to collapse where the floors are not designed for storage and were marked with "NO STORAGE" in 6 inch stenciling; the heights were:   a. above 9 feet (113") to the concrete floor below at the loft above the entrance to the back room; b. above 9 feet (103") to the concrete floor below at the loft above the rest room.
Recent events (2)
  • · I (S) $3492
  • · Z (S) $5000

1910.23 C01 I

Serious Gravity 10 2 instances 12 exposed
Issued
May 13, 2016
Abate by
Jun 8, 2016
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.23(c)(1)(i): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) and was not provided with a toeboard wherever, beneath the open sides, and whenever persons can pass:  On or about 4/14/2016 in the storage room: employees placing and removing materials such as but not limited to hardware and retail products into the loft areas are exposed to fall hazards where there were no railings installed, also workers passing below were exposed to potential struck-by hazards where there were no toe boards installed; the heights were:   a. above 9 feet (113") to the concrete floor below at the loft above the entrance to the back room; b. above 9 feet (103") to the concrete floor below at the loft above the rest room.
Recent events (2)
  • · I (S) $4900
  • · Z (S) $7000

1910.37 A03

Serious Gravity 1 1 instance 12 exposed
Issued
May 13, 2016
Abate by
May 25, 2016
Penalty
Initial $3,000 · Current $2,100 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  On or about 4/14/2016 in the back room; employees are exposed to smoke inhalation and burn hazards where the emergency exit door was "half-blocked" on a regular basis from the storage of stock merchandise.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $3000

1910.37 A04

Serious Gravity 1 1 instance 12 exposed
Issued
May 13, 2016
Abate by
May 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  On or about 4/14/2016, in the storage room; employees are exposed to smoke inhalation and thermal burn hazards where the designated emergency exit sign was not lit and emergency lighting did not work.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 G01 I A

Serious Gravity 1 2 instances 12 exposed
Issued
May 13, 2016
Abate by
May 25, 2016
Penalty
Initial $3,000 · Current $2,100 Reduced
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized; the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:   a. On or about 4/14/2016 in the storage room; employees were exposed to electrical shock hazards where the depth of the working space to access the right 208V/120V electrical panel was reduced to less than 36 inches by storage of merchandise.   b. On or about 4/14/2016 in the storage room; employees were exposed to electrical shock hazards where the depth of the working space to access to the left electrical panel was reduced to less than 36 inches by storage of merchandise.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $3000

1910.305 B01 II

Serious Gravity 10 1 instance 12 exposed
Issued
May 13, 2016
Abate by
May 25, 2016
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:  On or about 4/14/2016 in the storage room; employees were exposed to electrical shock hazards where the right 208V/120V electrical panel that is accessed twice per day to operate the fluorescent overhead lights and alarm system, was missing blanks over ports #36 & #39.
Recent events (2)
  • · I (S) $4900
  • · Z (S) $7000

View HOT Topic, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341398519.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.