Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FITZGERALD ROOFING COMPANY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FITZGERALD ROOFING COMPANY, LLC in 1662 WESTFIELD ST., WEST SPRINGFIELD, MA 01089 (NAICS 236118). OSHA activity number 341400356.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fitzgerald Roofing Company, LLC — free Get an email when a new federal OSHA severe-injury report for Fitzgerald Roofing Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1662 WESTFIELD ST.
City
WEST SPRINGFIELD
State
MA
ZIP
01089
Mailing
93 OSCEOLA LANE, LONGMEADOW, MA 01106
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Repeat Gravity 10 1 instance 1 exposed
Issued
May 13, 2016
Abate by
May 23, 2016
Penalty
Initial $15,400 · Current $8,000 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     1662 Westfield Street, West Springfield, Massachusetts; Employee was exposed to an unprotected fall of approximately 23.5 feet while working on the roof of a two story colonial style home.  The employee was wearing a harness but it was not connected to a lanyard with an anchor point.     Fitzgerald Roofing was previously cited for a repeat violation of this occupational safety and health standard 29 CFR 1926.501(b)(13) which was contained in OSHA inspection number 995842 citation 2 item 1 and inspection 760042 citation 2 item 1.  Inspection 995842 was affirmed as a final order on October 9, 2014.  Inspection 760042 citation 2 item 1 was affirmed as a final order on January 8, 2013.         Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
  • — I (R) $8000
  • — Z (R) $15400

1926.1053 B01

Repeat Gravity 10 2 instances 4 exposed
Issued
May 13, 2016
Abate by
May 23, 2016
Penalty
Initial $6,160 · Current $3,000 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    1662 Westfield Street (RT. 20), West Springfield, Massachusetts;  Ladders used to access the roof bracket scaffolds on the roof did not extend a minimum of 3 feet above the point of access.  The height of the eave to the ground was approximately 23.5 feet.       Fitzgerald Roofing was previously cited for a repeat violation of this occupational safety and health standard 29 CFR 1926.1053(b)(1) which was contained in OSHA inspection number 995842 citation 1 item 1a.  Inspection 995842 was affirmed as a final order on October 9, 2014.      Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
  • — I (R) $3000
  • — Z (R) $6160

1926.1053 B12

Repeat Gravity 10 1 instance 4 exposed
Issued
May 13, 2016
Abate by
May 23, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive side rails:  1662 Westfield Street (Route 20), West Springfield, Massachusetts; An aluminum ladder was set up and used to access the roof of the porch within 2 feet of the weatherhead and electrical meter for the residence.  The weather head was approximately 17 inches from the edge of the porch where the ladder was erected.    Fitzgerald Roofing was previously cited for a repeat violation of this occupational safety and health standard 29 CFR 1926.1053(b)(12) which was contained in OSHA inspection number 995842 citation 1 item 1b.  Inspection 995842 was affirmed as a final order on October 9, 2014.     Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

View Fitzgerald Roofing Company, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341400356.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.