CONSHOHOCKEN, PA —
OSHA Inspection: HARD HAT SERVICES, LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of HARD HAT SERVICES, LLC in 205 FAYETTE ST., CONSHOHOCKEN, PA 19428 (NAICS 238210). OSHA activity number 341402063.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HARD HAT SERVICES, LLC
- Site address
- 205 FAYETTE ST.
- City
- CONSHOHOCKEN
- State
- PA
- ZIP
- 19428
- Mailing
- 536 N TROOPER RD, NORRISTOWN, PA 19403
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 30
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.150 C01 I
- Issued
- Jun 8, 2016
- Penalty
- Initial $2,380 · Current $500 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof: a) 205 Fayette St., Conshohocken, PA, Worksite: On or about April 13, 2016, employees were performing commercial construction work, but fire extinguishers were not provided for each 3,000 square feet of the protected building area.
Recent events (2)
- — I (S) $500
- — Z (S) $2380
1926.403 I02 I
- Issued
- Jun 8, 2016
- Penalty
- Initial $2,380 · Current $2,380
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) 205 Fayette St., Conshohocken, PA, Worksite: On or about April 13, 2016, employees were performing electrical installation work on a panel, which contained live parts energized in excess of 50 volts, but the electrical panel covers were not installed to effectively close the live parts.
Recent events (2)
- — I (S) $2380
- — Z (S) $2380
More inspections in this industry (NAICS 238210)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341402063.