Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: NORTH AMERICAN FLIGHT SERVICES

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of NORTH AMERICAN FLIGHT SERVICES in 410 GREENFIELD AVE., BALLSTON SPA, NY 12020 (NAICS 488119). OSHA activity number 341406882.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch North American Flight Services for free Get an email when a new federal OSHA severe-injury report for North American Flight Services is published. One employer, no account, unsubscribe in one click.
Site address
410 GREENFIELD AVE.
City
BALLSTON SPA
State
NY
ZIP
12020
Mailing
405 GREENFIELD AVE., BALLSTON SPA, NY 12020
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488119
Employees
12
Ownership type
Private (A)

2 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 3, 2016
Abate by
Jul 8, 2016
Penalty
Initial $1,700 · Current $1,700
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a) On or about 04/18/2016, employees, on site, are adding Teledyne battery fluid, to aviation batteries. The battery fluid contains, sulfuric acid. Employees add to the batteries as needed. The task was last conducted a month ago. The employer did not provide an eye wash station and shower in the vicinity.
Recent events (1)
  • · Z (S) $1700

1910.253 B02 IV

Other-than-serious 1 instance 2 exposed
Issued
Jun 3, 2016
Abate by
Jun 23, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinder is designed to accept a cap, were not always be in place, hand-tight, except when cylinders are in use or connected for use:  a). On or about 4/18/16, on site, for employees conducting maintenance work on airplanes, to include filling oxygen tanks. Employees handle acetylene and oxygen gas tanks. The employer stored these gas tanks, that were not in use, without their caps.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341406882.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.