Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MCLENNAN INTERIORS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MCLENNAN INTERIORS in MAPLEWOOD 400 7TH NORTH STREET, LIVERPOOL, NY 13088 (NAICS 238310). OSHA activity number 341411635.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mclennan Interiors — free Get an email when a new federal OSHA severe-injury report for Mclennan Interiors is published. One employer, no account, unsubscribe in one click.
Establishment
MCLENNAN INTERIORS
Site address
MAPLEWOOD 400 7TH NORTH STREET
City
LIVERPOOL
State
NY
ZIP
13088
Mailing
4589 HOWLETT HILL ROAD, MARCELLUS, NY 13108
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.502 D15 II

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 20, 2016
Abate by
Jul 23, 2016
Penalty
Initial $2,800 · Current $700 Reduced
29 CFR 1926.502(d)(15)(ii): Anchorages used for attachment of personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, and not installed under the supervision of a qualified person.    a)  At the jobsite, on the rooftop, on or about 4/19/16:  The employer did not ensure that workers using personal fall arrest equipment, did so under the supervision of a competent person.  Workers used personal fall arrest equipment outside the design of that equipment when they attached snaphooks of lifelines directly back onto themselves and created the potential for failure by sideloading the snaphook keepers.  Workers used lifelines installed onto vent curbs not capable of supporting at least 5,000 pounds per attached employee.  Workers used lifelines with excessive length, ensuring a fall from the edge would not be prevented, as was the design of that equipment.  The equipment used was not designed for self-rescue and no pre-arrangements or planning was made for rescue if needed.  This was accomplished under the direct supervision of the Superintendent.    Abatement documentation must be submitted for this item.
Recent events (3)
  • — J (S) $700
  • — C (S) $2800
  • — Z (S) $2800

1926.502 D06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(6)(i): A snaphook not of the design type was engaged directly to webbing , such that unintentional disengagement could occur by the connected object being able to sideload the the snaphook keeper and release itself:  a)  At the jobsite, on the rooftop, on or about 4/19/16:  The Superintendent did not ensure that employees using personal fall arrest equipment, did so according to the design of that equipment by attaching the snaphooks of lifelines directly back onto themselves, creating the potential for failure by sideloading the snaphook keeper.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.502 D16 III

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:  a)  At the jobsite, on the rooftop, on or about 4/19/16:  The Superintendent did not ensure that employees using personal fall arrest equipment, did so according to the design of that equipment when workers used lifelines and rope grab devices with the ropes coaxed out to their furthest length, not preventing a fall from the edge of the building as the equipment is designed to do, and not preventing a free fall of more than 6 feet in the event of a fall.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.502 D20

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(20): The employer did not provide for prompt rescue of employees in the event of a fall or did not assure that employees were able to rescue themselves:  a)  At the jobsite, on the rooftop, on or about 4/19/16:  The Superintendent did not ensure that employees using personal fall arrest equipment were able to self rescue and had not coordinated to provide rescue if needed.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

View Mclennan Interiors's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341411635.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.