Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IAP WORLD SERVICES INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of IAP WORLD SERVICES INC. in 21967 CUDDIHY ROAD BUILDING 2187, PATUXENT RIVER, MD 20670 (NAICS 561210). OSHA activity number 341411734.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch IAP World Services INC. — free Get an email when a new federal OSHA severe-injury report for IAP World Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
21967 CUDDIHY ROAD BUILDING 2187
City
PATUXENT RIVER
State
MD
ZIP
20670
Mailing
P.O. BOX 809, PATUXENT RIVER, MD 20670
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561210
Employees
1600
Ownership type
A

2 citations on file for this inspection.

1910.138 A

Other-than-serious 1 instance 1 exposed
Issued
Oct 14, 2016
Abate by
Oct 24, 2016
Penalty
Initial $12,471 · Current $10,000 Reduced
29 CFR 1910.138(a): Appropriate hand protection was not used when employee's hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes:    On or about April 15, 2016, in the South Engineering Center, Office # 33181, an employee that was troubleshooting a motion sensor that was located in the ceiling was exposed to thermal burns hazards due to the lack of hand protection being worn by the employee.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $10000
  • — Z (S) $12471

1910.333 A01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Oct 14, 2016
Abate by
Oct 24, 2016
Penalty
Initial $12,471 · Current $0 Reduced
29 CFR 1910.333(a)(1): The employer failed to ensure that live parts were de-energized before employees began to work on or near live parts.  (a) Building 2187, South Engineering Center, Office # 33181 - An employee troubleshooting a faulty motion sensor in the office ceiling failed to de-energize the equipment, on or about 4/14/2016.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12471

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341411734.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.