Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DYNAMIC ENERGY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DYNAMIC ENERGY in 47 EPISCOPAL ROAD, BERLIN, CT 06037 (NAICS 238990). OSHA activity number 341412179.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dynamic Energy — free Get an email when a new federal OSHA severe-injury report for Dynamic Energy is published. One employer, no account, unsubscribe in one click.
Establishment
DYNAMIC ENERGY
Site address
47 EPISCOPAL ROAD
City
BERLIN
State
CT
ZIP
06037
Mailing
1550 LIBERTY RIDGE DRIVE, SUITE 310, WAYNE, PA 19087
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 6 exposed
Issued
Jun 10, 2016
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a)  47 Episcopal Road Job Site - On or about 4-18-16 - Employees were exposed to sixteen foot fall hazards while installing solar panels on the flat roof of a building with no fall protective systems in use.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1926.503 A02 III

Serious Gravity 10 1 instance 6 exposed
Issued
Jun 10, 2016
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used.  a)  47 Episcopal Road Job Site - 4-18-16 - Employees were exposed to 16 foot fall hazards through the use of improper fall protection systems while installing solar panels on a flat roof.  Warning line systems were being used to install solar panels which are only allowed for roofing operations.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Jun 10, 2016
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a)  47 Episcopal Road Job Site - On or about 4-18-16 - Fiberglass extension ladder used to gain access to the roof work area only extended 28 inches above the edge of the roof.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

View Dynamic Energy's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341412179.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.