DOWNSVILLE, WI —
OSHA Inspection: WAYNE PALLETS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WAYNE PALLETS, INC. in N2601 STATE HWY 25, DOWNSVILLE, WI 54735 (NAICS 321113). OSHA activity number 341413094.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WAYNE PALLETS, INC.
- Site address
- N2601 STATE HWY 25
- City
- DOWNSVILLE
- State
- WI
- ZIP
- 54735
- Mailing
- PO BOX 62, DOWNSVILLE, WI 54735
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 18
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 D03
- Issued
- Jul 27, 2016
- Abate by
- Sep 23, 2016
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: (a) Pallet mill; Energy isolation devices were not used during setup and jam clearing operations on the Cambell auto nailing machine.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.147 D04 I
- Issued
- Jul 27, 2016
- Abate by
- Aug 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees: (a) Throughout the pallet mill; Energy isolation (lockout) devices were not affixed to isolation points during setup and jam clearing operations on equipment including, but not limited to; i. Pallet nailing area; Cambell auto nailing machine during nail jam clearing operations, ii. Pallet nailing area; Cambell auto nailing machine during setup operations, iii. Stringer line; Changing sizer sawblades, and iv. Stringer line; Changing gang ripsaw blades.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Jul 27, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Pallet mill, Stringer line; Power transmission pulleys on the material positioner roller were not guarded.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.219 E01 I
- Issued
- Jul 27, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: (a) Pallet mill, Stringer line; A power transmission belt on the material positioner roller was not guarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Jul 27, 2016
- Abate by
- Aug 4, 2016
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) Pallet mill, Stringer line; Energized conductor wires for a powered conveyor were exposed because the cover plate was missing from the junction box they were in.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.147 C06 I
- Issued
- Jul 27, 2016
- Abate by
- Aug 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Throughout the facility; Energy isolation procedures were not evaluated within the last year.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.212 A02
- Issued
- Jul 27, 2016
- Abate by
- Aug 10, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: (a) Production areas; Guards are not secured and/or safeguarded to prevent them from being easily bypassed; i. Pallet mill; A wooden guard covering power transmission components on the chop saws discharge conveyor was not secured to prevent movement and/or bypass and ii. Saw mill; A wooden guard covering lower blade exposures under the double band saws was not secured to prevent movement and/or bypass.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.219 F03
- Issued
- Jul 27, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven feet or less above floors or platforms were not enclosed: (a) Pallet mill, Waste conveyor of chop saw; Chains and sprockets were not guarded on the waste conveyor.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Wayne Pallets, INC.
View Wayne Pallets, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341413094.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.