OSHA Inspection: FROYLAN BARRERA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FROYLAN BARRERA in 7211 GRUBER DR., MASON, OH 45040 (NAICS 238130). OSHA activity number 341417533.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Froylan Barrera — free Get an email when a new federal OSHA severe-injury report for Froylan Barrera is published. One employer, no account, unsubscribe in one click.
Establishment
FROYLAN BARRERA
Site address
7211 GRUBER DR.
City
MASON
State
OH
ZIP
45040
Mailing
1066 LEDRO STREET, CINCINNATI, OH 45241
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jun 3, 2016
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  Located on the north side of a residential structure, employees were observed performing framing work on a low sloped pitch roof while not utilizing an adequate fall protection system. Potential fall heights were measured to be 13'-3" with a roof pitch of 4 in12.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

View Froylan Barrera's full OSHA safety record →